RKC SB1 디지털 온도컨트롤러
RKC SB1 Digital controllers (Temperature controllers)
- Measurement accuracy: ±0.3% of displayed value
- Sampling time: 0.5 sec.
- Maximum 7A SSR can be incorporated
- Mounting method: DIN rail, Pipe hanging, or Pipe wrapping installation
- Loader communication is available
- Fully connector connection based
클릭 하시면 이동합니다.
알케이씨 ・ RKC
SB1
디지털 온도컨트롤러
SB1 Digital controllers (Temperature controllers)
Main features
- Maximum 7A SSR can be incorporated
![]() | This instrument can incorporate a 7A SSR and function as a temperature controller when it is connected to a power supply, a heater and a temperature sensor. |
- Installable in the interspace, in the empty space, or on the pipe
![]() | The installation method can be selected from a DIN rail mounting, a pipe hanging, or a pipe wrapping type. |
- Safety consideration <Load power supply cutoff + Built-in fuse>
![]() | The internal load power supply is cut off using the internal relay at the time of a loop break alarm (LBA) or a FAIL. A fuse is built in to function in case of a load short circuit. |
- Link operation for power saving <Peak current suppression function (SB Link)>
![]() | Link operation (up to four pieces) is available to avoid turning on of heaters simultaneously. Peak current can be suppressed. |
- Loader communication
![]() | Loader communication port is available. Configuration data management software (PROTEM2) is available |
External dimensions
SB1 SB1 RKC RKC SB1 SB1 알케이씨 알케이씨 SB1
가격이 궁금하신가요?
더 많은 자료는?
알케이씨 ・ RKC
SB1
디지털 온도컨트롤러
SB1 Digital controllers (Temperature controllers)
Main features
- Maximum 7A SSR can be incorporated
![]() | This instrument can incorporate a 7A SSR and function as a temperature controller when it is connected to a power supply, a heater and a temperature sensor. |
- Installable in the interspace, in the empty space, or on the pipe
![]() | The installation method can be selected from a DIN rail mounting, a pipe hanging, or a pipe wrapping type. |
- Safety consideration <Load power supply cutoff + Built-in fuse>
![]() | The internal load power supply is cut off using the internal relay at the time of a loop break alarm (LBA) or a FAIL. A fuse is built in to function in case of a load short circuit. |
- Link operation for power saving <Peak current suppression function (SB Link)>
![]() | Link operation (up to four pieces) is available to avoid turning on of heaters simultaneously. Peak current can be suppressed. |
- Loader communication
![]() | Loader communication port is available. Configuration data management software (PROTEM2) is available |
External dimensions