ISOTECH 988 BLACKBODY SOURCE
20°C to 45°C
First introduced to assist in relation to the SARS outbreak during the early 2000s the Model 988 is now helping in relation to coronavirus.
- Improves Accuracy of Fever Detection Systems
- Can be used either horizontally or vertically.
- Check Non-Contact Thermometers
- Features a high emissivity ridged plate that is 70 mm diameter
클릭 하시면 이동합니다.
아이소텍 ・ ISOTECH
988
BLACKBODY SOURCE
First introduced to assist in relation to the SARS outbreak during the early 2000s the Model 988 is now helping in relation to coronavirus. It can be used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications. It can also be used to check non-contact clinical thermometers.
This blackbody meets the demand for a simple, cost effective but high accuracy calibrator for the calibration of thermal imagers and infrared thermometers used at temperatures around human body temperature.
A 70 mm diameter ridged plate is heated or cooled with an internal solid state thermoelectric heat pump. The temperature of the plate can be set from 20°C to 45°C to a resolution of 0.1°C.
The standard version has a 210mm long tube mainly used with thermal imagers. A second version has a 40mm tube more suited for checking medical thermometers.
- SPECIFICATION
Model | 988 |
Temperature Range | 20°C to 45°C |
Resolution | ±0.1°C |
Target Size | 70mm Diameter |
Sighting Tube Diameter | 54mm Diameter |
Emissivity | 0.97 ± 0.02 |
Combined Accuracy / Stability | ±0.2°C (±0.3°F) |
Power | 60 Watts |
Voltage | 12 Vdc |
Dimensions | Height 230mm Width 225mm Depth 115mm |
Weight | 4kg |
Optional PC Interface | |
Accessories | Switch Mode Power Supply Supplied as Standard 100-240 VAC |
How to order | Model 988 |
가격이 궁금하신가요?
더 많은 자료는?
아이소텍 ・ ISOTECH
988
BLACKBODY SOURCE
First introduced to assist in relation to the SARS outbreak during the early 2000s the Model 988 is now helping in relation to coronavirus. It can be used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications. It can also be used to check non-contact clinical thermometers.
This blackbody meets the demand for a simple, cost effective but high accuracy calibrator for the calibration of thermal imagers and infrared thermometers used at temperatures around human body temperature.
A 70 mm diameter ridged plate is heated or cooled with an internal solid state thermoelectric heat pump. The temperature of the plate can be set from 20°C to 45°C to a resolution of 0.1°C.
The standard version has a 210mm long tube mainly used with thermal imagers. A second version has a 40mm tube more suited for checking medical thermometers.
- SPECIFICATION
Model | 988 |
Temperature Range | 20°C to 45°C |
Resolution | ±0.1°C |
Target Size | 70mm Diameter |
Sighting Tube Diameter | 54mm Diameter |
Emissivity | 0.97 ± 0.02 |
Combined Accuracy / Stability | ±0.2°C (±0.3°F) |
Power | 60 Watts |
Voltage | 12 Vdc |
Dimensions | Height 230mm Width 225mm Depth 115mm |
Weight | 4kg |
Optional PC Interface | |
Accessories | Switch Mode Power Supply Supplied as Standard 100-240 VAC |
How to order | Model 988 |