클릭 하시면 이동합니다.
아이소텍 ・ ISOTECH
984
GAS FLOW SYSTEM
The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low temperatures but increases at higher temperatures.
For Indium and Tin cells the effect is small and for Indium, Tin and Zinc cells in general no attention needs to be made. Yet for Aluminium, Silver and Copper Cells the oxygen must be excluded or the cells would be quickly damaged.
The Model 984 Gas Flow System connects between an inert gas supply, such as Argon or Nitrogen and the Cell in its apparatus. The Model 984 has a regulator and a flow meter optimised to easily set the flow to 0.2 L/min and features an audible alarm should the gas flow be interrupted.
- SPECIFICATION
| Model | 984 |
| Input-Output Connectors | Genevac 16KF |
| Alarm | Audible |
| Power | 15 Watts |
| Voltage | 12Vdc |
| Dimensions | Height 240mm Width 120mm Depth 220mm (excluding connection pipes) |
| Weight | 2.5kg |
| How to order | Model 984 Gas Flow System: Supplied with external power supply, 2 x connecting pipes and fittings. |

가격이 궁금하신가요?
더 많은 자료는?


지니어스인더스트리가 취급하는 대부분의 제품은 사업자 간 거래(B2B) 목적의 산업·연구용 전문 계측 장비입니다.
모든 제품은 주문 제작 또는 해외/본사 주문을 통해 공급되고 있으며 실제 현장/시험 환경에서 사용되는 특성상, 장비 개봉, 전원 인가, 설치/시운전, 교정(캘리브레이션) 진행 등으로 제품의 신뢰도와 가치가 달라지기 때문에 일반 소비재와 달리 단순 변심 사유의 반품·환불이 어렵습니다.
다만 초기 제품 하자(동일 모델 대비 명백한 불량, 운송 중 파손, 사양 상이 등)가 확인되는 경우에는 수령 후 [7일 이내] 연락 주시면 점검 후 조치 또는 A/S 절차를 안내해 드리고 있습니다.
단순 변심, 사양 선택 착오, 내부 사정(예: 예산/프로젝트 변경 등)과 같은 구매자 사유로 반품을 요청하시는 경우에는 반품이 제한되며, 예외적으로 협의가 진행될 경우에도 왕복 운송비, 검수 비용, 감가 비용 및 재입고 수수료 등이 청구될 수 있습니다.
구체적인 거래 조건(납기, A/S 범위, 교환 가능 여부 등)은 발행된 견적서, 발주서 확인 메일, 납품서 등에 명시된 내용을 우선합니다.
도움이 필요한 경우 견적서에 명시된 지니어스 영업부 담당자에게 문의해 주시기 바랍니다.
아이소텍 ・ ISOTECH
984
GAS FLOW SYSTEM
The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low temperatures but increases at higher temperatures.
For Indium and Tin cells the effect is small and for Indium, Tin and Zinc cells in general no attention needs to be made. Yet for Aluminium, Silver and Copper Cells the oxygen must be excluded or the cells would be quickly damaged.
The Model 984 Gas Flow System connects between an inert gas supply, such as Argon or Nitrogen and the Cell in its apparatus. The Model 984 has a regulator and a flow meter optimised to easily set the flow to 0.2 L/min and features an audible alarm should the gas flow be interrupted.
- SPECIFICATION
| Model | 984 |
| Input-Output Connectors | Genevac 16KF |
| Alarm | Audible |
| Power | 15 Watts |
| Voltage | 12Vdc |
| Dimensions | Height 240mm Width 120mm Depth 220mm (excluding connection pipes) |
| Weight | 2.5kg |
| How to order | Model 984 Gas Flow System: Supplied with external power supply, 2 x connecting pipes and fittings. |

가격이 궁금하신가요?
더 많은 자료는?


지니어스인더스트리가 취급하는 대부분의 제품은 사업자 간 거래(B2B) 목적의 산업·연구용 전문 계측 장비입니다.
모든 제품은 주문 제작 또는 해외/본사 주문을 통해 공급되고 있으며 실제 현장/시험 환경에서 사용되는 특성상, 장비 개봉, 전원 인가, 설치/시운전, 교정(캘리브레이션) 진행 등으로 제품의 신뢰도와 가치가 달라지기 때문에 일반 소비재와 달리 단순 변심 사유의 반품·환불이 어렵습니다.
다만 초기 제품 하자(동일 모델 대비 명백한 불량, 운송 중 파손, 사양 상이 등)가 확인되는 경우에는 수령 후 [7일 이내] 연락 주시면 점검 후 조치 또는 A/S 절차를 안내해 드리고 있습니다.
단순 변심, 사양 선택 착오, 내부 사정(예: 예산/프로젝트 변경 등)과 같은 구매자 사유로 반품을 요청하시는 경우에는 반품이 제한되며, 예외적으로 협의가 진행될 경우에도 왕복 운송비, 검수 비용, 감가 비용 및 재입고 수수료 등이 청구될 수 있습니다.
구체적인 거래 조건(납기, A/S 범위, 교환 가능 여부 등)은 발행된 견적서, 발주서 확인 메일, 납품서 등에 명시된 내용을 우선합니다.
도움이 필요한 경우 견적서에 명시된 지니어스 영업부 담당자에게 문의해 주시기 바랍니다.