ISOTECH 944 SURFACE MEASUREMENT
ISOTECH 944 SURFACE MEASUREMENT
30°C to 350°C
The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that the temperature indicated by the hot plate is not necessarily the temperature at the point of measurement.
- Indicates True Surface Temperature
- 30°C to 350°C
- Resolution 0.1°C
원산지 U.K
제조사 ISOTECH
브랜드 ISOTECH
무게 1kg
택배 · 기본 무료
클릭 하시면 이동합니다.
아이소텍 ・ ISOTECH
944
SURFACE MEASUREMENT
The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that the temperature indicated by the hot plate is not necessarily the temperature at the point of measurement.
An ideal system would not disturb the heat-flux from the hot-plate.
During 1993 such a system was described (ref. “Progress in Contact Thermometry” 1993 B. D. Foulis) and Isotech have the inventor’s permission to make and market the device World-wide.
- Principal of Operation
A fine wire type N thermocouple is used as the surface temperature sensor, a second junction 2 to 3mm along the thermocouple, senses the temperature difference due to heat flux along the sensor.
A heater heats the thermocouple stem until the temperature gradient is zero, thus creating a measurement without stem conduction, or disturbance of the hot-plate’s surface.
The 944 can be used with the Isotech Small Hot Plate model 983. A traceable calibration certificate is available to order.
- SPECIFICATION
| Model | 944 True Surface Temperature Measurement System |
| Temperature Range | 30°C to 350°C |
| Resolution of Display | 0.1°C or 0.1°F |
| Stability | ±0.1°C |
| Accuracy | ±2°C with TRACEABLE Certification ±5°C without Certification |
| Probe Assembly | Probe Diameter – 7.5mm Probe Length – 150mm Lead Length – 850mm |
| Power Supply | 100V – 120V, 50/60Hz or 200V – 240V, 50/60Hz |
| Dimensions | Height 90mm Width 153mm Depth 265mm (excluding plugs) |
| Weight | 4kg |
| How to order | Model 944 & Probe 935-14-81 Please state supply voltage required. Please state if Calibration is required. |

가격이 궁금하신가요?
더 많은 자료는?



(주)지니어스허브가 만든 플랫폼 '지니어스인더스트리'는 사업자 간 거래(B2B) 목적의 산업·연구용 계측장비/시스템 유통 플랫폼입니다.
모든 제품은 주문 제작 또는 해외/본사 주문을 통해 공급되고 있으며 실제 현장/시험 환경에서 사용되는 특성상, 장비 개봉, 전원 인가, 설치/시운전, 교정(캘리브레이션) 진행 등으로 제품의 신뢰도와 가치가 달라지기 때문에 일반 소비재와 달리 단순 변심 사유의 반품·환불이 어렵습니다. 다만 초기 제품 하자(동일 모델 대비 명백한 불량, 운송 중 파손, 사양 상이 등)가 확인되는 경우에는 수령 후 [7일 이내] 연락 주시면 점검 후 조치 또는 A/S 절차를 안내해 드리고 있습니다.
단순 변심, 사양 선택 착오, 내부 사정(예: 예산/프로젝트 변경 등)과 같은 구매자 사유로 반품을 요청하시는 경우에는 반품이 제한되며, 예외적으로 협의가 진행될 경우에도 왕복 운송비, 검수 비용, 감가 비용 및 재 입고 수수료 등이 청구될 수 있습니다. 구체적인 거래 조건(납기, A/S 범위, 교환 가능 여부 등)은 발행된 견적서, 발주서 확인 메일, 납품서 등에 명시된 내용을 우선합니다. 기타 도움이 필요한 경우 견적서에 명시된 지니어스 영업부 담당자에게 문의해 주시기 바랍니다.
아이소텍 ・ ISOTECH
944
SURFACE MEASUREMENT
The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that the temperature indicated by the hot plate is not necessarily the temperature at the point of measurement.
An ideal system would not disturb the heat-flux from the hot-plate.
During 1993 such a system was described (ref. “Progress in Contact Thermometry” 1993 B. D. Foulis) and Isotech have the inventor’s permission to make and market the device World-wide.
- Principal of Operation
A fine wire type N thermocouple is used as the surface temperature sensor, a second junction 2 to 3mm along the thermocouple, senses the temperature difference due to heat flux along the sensor.
A heater heats the thermocouple stem until the temperature gradient is zero, thus creating a measurement without stem conduction, or disturbance of the hot-plate’s surface.
The 944 can be used with the Isotech Small Hot Plate model 983. A traceable calibration certificate is available to order.
- SPECIFICATION
| Model | 944 True Surface Temperature Measurement System |
| Temperature Range | 30°C to 350°C |
| Resolution of Display | 0.1°C or 0.1°F |
| Stability | ±0.1°C |
| Accuracy | ±2°C with TRACEABLE Certification ±5°C without Certification |
| Probe Assembly | Probe Diameter – 7.5mm Probe Length – 150mm Lead Length – 850mm |
| Power Supply | 100V – 120V, 50/60Hz or 200V – 240V, 50/60Hz |
| Dimensions | Height 90mm Width 153mm Depth 265mm (excluding plugs) |
| Weight | 4kg |
| How to order | Model 944 & Probe 935-14-81 Please state supply voltage required. Please state if Calibration is required. |