대한민국 No.1 산업장비 공급채널

아래 검색창을 통해 궁금하신 제품의 모델명을 검색해보세요.

최신 기준으로 전 우주에서 수집한 제품 관련 자료를 전부 보여드립니다.

ISOTECH판매중인 아이소텍 ISOTECH 제품 리스트

CUSTOMER:                                           ORDER NO: 
    
  
Jarrett-Isotech Range Water Triple Point Cells                                          
With Certificate of Conformity  
  
Borosilicate  
A11/50/270Temperature, 0.01°C
A13/50/270Temperature, 0.01°C
B11/50/270Temperature, 0.01°C
B11/65/270Temperature, 0.01°C
B13/65/270Temperature, 0.01°C
B16/65/270Temperature, 0.01°C
  
Quartz 
A11/50/270QTemperature, 0.01°C
B11/50/270QTemperature, 0.01°C
B11/65/270QTemperature, 0.01°C
  
Isotech Water Triple Point Cells
With Certificate of Conformity
  
B8/30/130Temperature, 0.01°C
B12/40/210Temperature, 0.01°C
B12/46/210Temperature, 0.01°C
  
Calibration OptionTraceable and UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
    
Maintenance Bath Water Triple Point
For the maintenance of 1 to 4 Water Triple Point Cells
    
    
18233Water Triple Point Maintenance Bath
 Temperature Range 0.01°C  
    
Voltage Supply 100/130V – 50/60Hz
 208/240V – 50/60Hz
    
    
SpecifyPlease specify which type of Triple Point of Water Cell will be used so that we can supply the correct cell holder
    
    
Ice Mantle Maker Water Triple Point  
For use with Large Water Triple Point Cells. Includes 1 x Ice Bridge Prevention Collar
  
    
452Ice Mantle Maker
    
Accessories   
451-01-04Additional Ice Bridge Prevention Collar
    
    
SpecifyIce Bridge Prevention Collars are manufactured to suit the cell in use, please specify the following:
    
 Cell Type  
 Outside Diameter of Water Triple Point Cell (mm)
 Depth from shoulder of Cell to water level (mm)
    
    
Sostmann-Isotech Gallium Cell Sealed  
Includes Certificate of Conformity  
    
    
17401Sostmann-Isotech Gallium Cell  
 Temperature Range 29.7646°C  
    
    
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
    
    
Hazardous     (consult Isotech)Due to the hazardous nature of the Gallium, the cells are packed and shipped in accordance with IATA specifications
    
    
Apparatus Gallium  
For the realization and maintenance of the Gallium Cell automatically
    
    
17402BGallium Apparatus   
 Temperature Range 29.7646°C  
    
Voltage Supply 100/130V – 50/60Hz
 208/240V – 50/60Hz
    
    
Isotech Mercury Cell   
Includes Certificate of Conformity  
    
    
17724Mercury Triple Point Cell   
 Temperature Range -38.8344°C  
    
    
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
    
    
Hazardous     (consult Isotech)Due to the hazardous nature of the Mercury the cells are packed and shipped in accordance with IATA specifications
    
    
Apparatus Mercury Triple Point Model  
A cryostat to realise the Triple Point of Mercury  
    
    
17725Mercury Triple Point Apparatus
 Temperature Range -36°C to -42°C
    
Voltage Supply  208/240V – 50Hz  
  208/240V – 60Hz  
    
    
Triple Point Apparatus Simple Argon 
For the realisation of the Argon Triple Point  
  
471Triple Point Apparatus Simple Argon
 Temperature Range -189.3442°C