아래 검색창을 통해 궁금하신 제품의 모델명을 검색해보세요.
최신 기준으로 전 우주에서 수집한 제품 관련 자료를 전부 보여드립니다.
ISOTECH판매중인 아이소텍 ISOTECH 제품 리스트
CUSTOMER: ORDER NO: | |||
Jarrett-Isotech Range Water Triple Point Cells | |||
With Certificate of Conformity | |||
Borosilicate | |||
A11/50/270 | Temperature, 0.01°C | ||
A13/50/270 | Temperature, 0.01°C | ||
B11/50/270 | Temperature, 0.01°C | ||
B11/65/270 | Temperature, 0.01°C | ||
B13/65/270 | Temperature, 0.01°C | ||
B16/65/270 | Temperature, 0.01°C | ||
Quartz | |||
A11/50/270Q | Temperature, 0.01°C | ||
B11/50/270Q | Temperature, 0.01°C | ||
B11/65/270Q | Temperature, 0.01°C | ||
Isotech Water Triple Point Cells | |||
With Certificate of Conformity | |||
B8/30/130 | Temperature, 0.01°C | ||
B12/40/210 | Temperature, 0.01°C | ||
B12/46/210 | Temperature, 0.01°C | ||
Calibration Option | Traceable and UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties | ||
Maintenance Bath Water Triple Point | |||
For the maintenance of 1 to 4 Water Triple Point Cells | |||
18233 | Water Triple Point Maintenance Bath | ||
Temperature Range 0.01°C | |||
Voltage Supply | 100/130V – 50/60Hz | ||
208/240V – 50/60Hz | |||
Specify | Please specify which type of Triple Point of Water Cell will be used so that we can supply the correct cell holder | ||
Ice Mantle Maker Water Triple Point | |||
For use with Large Water Triple Point Cells. Includes 1 x Ice Bridge Prevention Collar | |||
452 | Ice Mantle Maker | ||
Accessories | |||
451-01-04 | Additional Ice Bridge Prevention Collar | ||
Specify | Ice Bridge Prevention Collars are manufactured to suit the cell in use, please specify the following: | ||
Cell Type | |||
Outside Diameter of Water Triple Point Cell (mm) | |||
Depth from shoulder of Cell to water level (mm) | |||
Sostmann-Isotech Gallium Cell Sealed | |||
Includes Certificate of Conformity | |||
17401 | Sostmann-Isotech Gallium Cell | ||
Temperature Range 29.7646°C | |||
Calibration Option | UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties | ||
Hazardous (consult Isotech) | Due to the hazardous nature of the Gallium, the cells are packed and shipped in accordance with IATA specifications | ||
Apparatus Gallium | |||
For the realization and maintenance of the Gallium Cell automatically | |||
17402B | Gallium Apparatus | ||
Temperature Range 29.7646°C | |||
Voltage Supply | 100/130V – 50/60Hz | ||
208/240V – 50/60Hz | |||
Isotech Mercury Cell | |||
Includes Certificate of Conformity | |||
17724 | Mercury Triple Point Cell | ||
Temperature Range -38.8344°C | |||
Calibration Option | UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties | ||
Hazardous (consult Isotech) | Due to the hazardous nature of the Mercury the cells are packed and shipped in accordance with IATA specifications | ||
Apparatus Mercury Triple Point Model | |||
A cryostat to realise the Triple Point of Mercury | |||
17725 | Mercury Triple Point Apparatus | ||
Temperature Range -36°C to -42°C | |||
Voltage Supply | 208/240V – 50Hz | ||
208/240V – 60Hz | |||
Triple Point Apparatus Simple Argon | |||
For the realisation of the Argon Triple Point | |||
471 | Triple Point Apparatus Simple Argon | ||
Temperature Range -189.3442°C | |||
Hazardous (consult Isotech) | Due to the hazardous nature of the Argon the apparatus is packed and shipped in accordance with IATA specifications | ||
Fixed Point Cells Optimal - SEALED | |||
99.9999% Pure. Includes Certificate of Conformity | |||
QUARTZ Clad Sealed Fixed Point Cells | |||
Require to be hand carried | |||
17668 | Indium 156.5985°C | ||
17669 | Tin 231.928°C | ||
17671 | Zinc 419.527°C | ||
17672 | Aluminum 660.323°C | ||
17673 | Silver 961.78°C | ||
17674 | Copper 1084.62°C | ||
METAL Clad Sealed Fixed Point Cells | |||
Transportable | |||
17668MO | Indium 156.5985°C | ||
17669MO | Tin 231.928°C | ||
17671MO | Zinc 419.527°C | ||
17672MO | Aluminum 660.323°C | ||
Accessories | Basket and heat shunts are required for the cells when used with Isotech Furnaces | ||
Basket Assemblies for Isotech furnaces (excluding 465) | |||
410-07-01 Type B | Optimal Cell Basket Assembly - Indium, Tin (nett) | ||
410-07-01 Type B | Optimal Cell Basket Assembly - Zinc (nett) | ||
410-07-01 Type B | Optimal Cell Basket Assembly - Aluminium, Silver, Copper (nett) | ||
Basket Assemblies for Isotech 465 only | |||
465-04-02 | Optimal Cell Basket Assembly for Tin and Zinc (nett) | ||
465-04-01 | Optimal Cell Basket Assembly - Aluminium, Silver, Copper (nett) | ||
Calibration Option | UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties | ||
Hand Carry Recommendation | Quartz Cells require to be hand carried however due to hand carry restrictions imposed by the airlines this may not be possible. For more information regarding hand carry please consult with Isotech. | ||
Fixed Point Cells Optimal - OPEN | |||
99.9999% Pure. Includes Certificate of Conformity | |||
QUARTZ Open Fixed Point Cell | |||
Transportable | |||
17668QCO | Indium 156.5985°C | ||
17669QCO | Tin 231.928°C | ||
17671QCO | Zinc 419.527°C | ||
17672QCO | Aluminum 660.323°C | ||
17673QCO | Silver 961.78°C | ||
17674QCO | Copper 1084.62°C | ||
For Quartz Open Fixed Point Cells only please specify length required | |||
Design type A | Crucible Length 460mm ±2mm | ||
Re-Entrant Length 450mm ±2mm | |||
Design type B | Crucible Length 520mm ±2mm | ||
Re-Entrant Length 510mm ±2mm | |||
Design type C | Crucible Length 620mm ±2mm | ||
Re-Entrant Length 610mm ±2mm | |||
METAL Open Fixed Point Cell | |||
Transportable | |||
17668MCO | Indium 156.5985°C | ||
17669MCO | Tin 231.928°C | ||
17671MCO | Zinc 419.527°C | ||
17672MCO | Aluminum 660.323°C | ||
Sostmann-Isotech Gallium Cell | |||
99.99999% Pure. Includes Certificate of Conformity | |||
METAL Open Fixed Point Cell | |||
17401 (0) | Sostmann-Isotech Gallium Cell 29.7646°C | ||
Calibration Option | UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties | ||
Hazardous (consult Isotech) | Due to the hazardous nature of the Gallium the cells are packed and shipped in accordance with IATA specifications | ||
Furnaces - Dual | |||
For operation from Indium to Copper Fixed Points | |||
Includes 425-06-01 gantry holder for thermometers | |||
17707 | Low Temperature Dual Furnace | ||
Temperature Range 125°C to 250°C | |||
For Indium and Tin Fixed Points | |||
Voltage Supply | 108/115V – 50/60Hz | ||
208/240V – 50/60Hz | |||
17706 | High Temperature Dual Furnace | ||
Temperature Range 400°C to 1000°C | |||
For Zinc, Aluminium and Silver Fixed Points | |||
Voltage Supply | 110V – 50/60Hz | ||
230V – 50/60Hz | |||
17705 | Very High Temperature Dual Furnace | ||
Temperature Range 500°C to 1090°C | |||
For Aluminium, Silver and Copper Fixed Points | |||
Voltage Supply | 110V – 50/60Hz | ||
230V – 50/60Hz | |||
Accessories | |||
420-02-15 | Inconel Equalising Block (17705, 17706) | ||
410-02-18 | Aluminium Equalising Block (17707) | ||
824-01-00 | Fan Assembly to cool thermometer handle | ||
425-06-01 | Gantry Holder for Thermometers | ||
Furnaces - Heat Pipe | |||
For operation from Indium to Copper Fixed Points | |||
Includes 425-06-01 gantry holder for thermometers | |||
17702W | Low Temperature Heat Pipe Furnace | ||
Temperature Range 125°C to 250°C | |||
For Indium and Tin Fixed Points | |||
Voltage Supply | 108/115V – 50/60Hz | ||
208/240V – 50/60Hz | |||
17702P | High Temperature Heat Pipe Furnace | ||
Temperature Range 400°C to 1000°C | |||
For Zinc, Aluminium and Silver Fixed Points | |||
Voltage Supply | 110V – 50/60Hz | ||
230V – 50/60Hz | |||
17702S | Very High Temperature Heat Pipe Furnace | ||
Temperature Range 500°C to 1090°C | |||
For Aluminium, Silver and Copper Fixed Points | |||
Voltage Supply | 110V – 50/60Hz | ||
230V – 50/60Hz | |||
Accessories | |||
420-02-15 | Inconel Equalising Block (17702P, 17702S) | ||
410-02-18 | Alunimium Equalising Block (17702W) | ||
824-01-00 | Fan Assembly to cool thermometer handle | ||
411-01-11B | Annealing Adaptor | ||
425-06-01 | Gantry Holder for Thermometers | ||
Furnaces - Low Temperature | |||
For Indium, Tin and Zinc Fixed Points | |||
Includes 425-06-01 gantry holder for thermometers | |||
17701 | Low Temperature Furnace Model | ||
Temperature Range 50°C to 500°C | |||
Accessories | |||
824-01-00 | Fan Assembly to cool thermometer handle | ||
411-01-11 | Annealing Adaptor | ||
425-06-01 | Gantry Holder for Thermometers | ||
Voltage Supply | 108/130V – 50/60Hz | ||
208/240V – 50/60Hz | |||
Furnaces - Medium Temperature | |||
For Indium, Tin, Zinc and Aluminium Fixed Points | |||
Includes 425-06-01 gantry holder for thermometers | |||
17703 | Medium Temperature Furnace Model | ||
Temperature Range 50°C to 700°C | |||
Accessories | |||
824-01-00 | Fan Assembly to cool thermometer handle | ||
411-01-11B | Annealing Adaptor | ||
420-02-14 | Aluminium Bronze Equalising Block | ||
425-06-01 | Gantry Holder for Thermometers | ||
Voltage Supply | 108/130V – 50/60Hz | ||
208/240V – 50/60Hz | |||
Furnaces - 3 Zone High Temperature | |||
For Zinc, Aluminium, Silver, Gold and Copper Fixed Points | |||
Includes 425-06-01 gantry holder for thermometers | |||
465 | 3 Zone High Temperature Furnace | ||
Temperature Range 250°C to 1200°C | |||
Voltage Supply | 108/130V – 50/60Hz | ||
208/240V – 50/60Hz | |||
Accessories | Basket and heat shunts are required for the cells when used with Isotech Furnaces | ||
465-04-02 | Optimal Cell Basket Assembly for Tin and Zinc (nett) | ||
465-04-01 | Optimal Cell Basket Assembly for Aluminium, Silver and Copper (nett) | ||
465-02-06 | Ceramic Equalising Block | ||
425-06-01 | Gantry Holder for Thermometers | ||
Furnaces - Annealing | |||
For the pre-warming, annealing and cool down of SPRTS | |||
414 | Annealing Furnace | ||
Ambient to 1000°C with single ramp to set point | |||
Voltage Supply | 110V – 50/60Hz | ||
240V – 50/60Hz | |||
Primary SPRT - 670/25.5Ω | |||
Includes traceable certificate at Rtpw and Wga and carrying case | |||
Quartz | |||
670SQ/25.5Ω | Temperature Range -200°C to 670°C | ||
Length 480mm | |||
Length 650mm | |||
Metal | |||
670SH/25.5Ω | Temperature Range -80°C to 670°C | ||
Length 480mm | |||
Length 650mm | |||
Metal | |||
670SL/25.5Ω | Temperature Range -200°C to 165°C | ||
Length 480mm | |||
Calibration Option | UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties | ||
Hand Carry Recommendation | We recommend that these thermometers are hand carried where possible | ||