ISOTECH판매중인 ISOTECH 제품 리스트



Isocal-6 Range - Hyperion 4936 
Includes magnetic stirrer, probe basket, lid and 3 point traceable certificate
  
4936Hyperion 4000 Series
 Temperature Range -25°C to 140°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
Stirred Liquid Bath/Stirred Ice/Water Bath
936-06-02Stirred Liquid Container Kit
936-06-08Support Kit Assembly for up to 8 thermometers
Metal Block Bath
936-06-01aStandard Insert - 8 x 8mm x 2 x 4.5mm x 157mm deep
936-06-01bBlank Insert
936-06-01cNon Standard Insert (consult Isotech)
935-14-61/DBSemi-Standard PRT - Temperature Range  -50°C to 250°C
935-14-75/DB90° Angled Semi-Standard PRT - Temperature Range -50°C to 250°C
Blackbody Source
936-06-03Blackbody Target
Surface Sensor Calibrator
936-06-04Surface Sensor Calibrator Kit
ITS-90 Fixed Point Apparatus
17401 MSlim Gallium Melt Point Cell 
B8/30/130Water Triple Point Cell
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett) 
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
936-06-071 Litre C10 Silicon Oil (-35°C to 140°C) (½L Required)
932-12-74Replacement Liquid Container Magnetic Follower (Qty 5)
935-14-114Replacement Surface Sensor Probe
936-02-07Replacement Surface Sensor Insert
936-06-09Slim WTP Cell & Gallium Cell Holder Assembly
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-112Carrying Case with wheels and pull out handle (nett)
  
Voltage supply108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Isocal-6 Range - Drago 4934
Includes magnetic stirrer, probe basket, lid and 3 point traceable certificate
  
4934Drago 4000 Series
 Temperature Range 30°C to 250°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
Stirred Liquid Bath/Stirred Ice/Water Bath
936-06-02Stirred Liquid Container Kit
936-06-08Support Kit Assembly for up to 8 thermometers
Metal Block Bath
936-06-01aStandard Insert - 8 x 8mm x 2 x 4.5mm x 157mm deep
936-06-01bBlank Insert
936-06-01cNon Standard Insert (consult Isotech)
935-14-61/DBSemi Standard PRT - Temperature Range  -50°C to 250°C
935-14-75/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 250°C
Blackbody Source
936-06-03Blackbody Target
Surface Sensor Calibrator
936-06-04Surface Sensor Calibrator Kit
ITS-90 Fixed Point Apparatus
17401 MSlim Gallium Melt Point Cell 
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
580-06-091 Litre C20 Silicon Oil (20°C to 200°C) (½L Required)
915/091 Litre VHT Silicon Oil (150°C to 250°C) (½L Required)
935-14-114Replacement Surface Sensor Probe
936-02-07Replacement Surface Sensor Insert
936-06-09Slim Gallium Cell Holder Assembly
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-112Carrying Case with wheels and pull out handle (nett)
  
Voltage supply108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Isocal-6 Range - Europa 4520
Includes standard insert and 3 point traceable certificate
  
4520Europa 4000 Series
 Temperature Range -45°C to 140°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
Metal Block Bath 
951-02-15Additional Standard Insert -2x4.5mm, 2x6.4mm, 1x8mm, 1x9.5mm x 157mm deep
951-02-15aBlank Insert
951-02-15cNon Standard Insert (consult Isotech)
951-06-07Alternative insert type B - 1x13mm,1x10mm, 1x8mm,1x5mm, 1x3.5mm x 157mm deep
951-06-08Alternative insert type C - 1x8mm, 6x6.5mm x 157mm deep
935-14-82/DBSemi Standard PRT - Temperature Range  -50°C to 250°C
935-14-75/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 250°C
Stirred Liquid Bath/Stirred Ice/Water Bath
951-06-01Stirred Liquid Container Kit
921-02-06Liquid in Glass Thermometer Support Kit 
Blackbody Source 
951-06-04Blackbody Target
Surface Sensor Calibrator
951-06-02Surface Sensor Calibrator Kit
ITS-90 Fixed Point Apparatus
17401 MSlim Gallium Melt Point Cell 
17724 MSlim Mercury Melt Point Cell and Insulation Assembly
B8/30/130Water Triple Point Cell, Container and 3 Caps
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
520-05-01C10 Silicon Oil (-35°C to 140°C) 0.1L required
932-12-55Replacement Liquid Container Magnetic Follower (Qty 5)
935-14-83Replacement Surface Sensor Probe
951-02-19Replacement Surface Sensor Insert
951-02-29Slim WTP Cell Container (nett)
951-02-30Slim WTP Cell Container Caps (nett)
520-03-00Slim Mercury Cell Insulation Assembly (nett)
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage supply108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Isocal-6 Range - Venus 4951
Includes standard insert and 3 point traceable certificate
  
4951Venus 4000 Series
 Temperature Range -35°C to 140°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
Metal Block Bath 
951-02-15Additional Standard Insert -2x4.5mm, 2x6.4mm, 1x8mm, 1x9.5mm x 157mm deep
951-02-15aBlank Insert
951-02-15cNon Standard Insert (consult Isotech)
951-06-07Alternative insert type B - 1x13mm,1x10mm, 1x8mm,1x5mm, 1x3.5mm x 157mm deep
951-06-08Alternative insert type C - 1x8mm, 6x6.5mmx157mm deep
935-14-82/DBSemi Standard PRT - Temperature Range  -50°C to 250°C
935-14-75/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 250°C
Stirred Liquid Bath/Stirred Ice/Water Bath
951-06-01Stirred Liquid Container Kit
921-02-06Liquid in Glass Thermometer Support Kit 
Blackbody Source 
951-06-04Blackbody Target
Surface Sensor Calibrator
951-06-02Surface Sensor Calibrator Kit
ITS-90 Fixed Point Apparatus
17401 MSlim Gallium Melt Point Cell 
B8/30/130Water Triple Point Cell, Container and 3 Caps
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
520-05-01C10 Silicon Oil (-35°C to 140°C) 0.1L required
932-12-55Replacement Liquid Container Magnetic Follower (Qty 5)
935-14-83Replacement Surface Sensor Probe
951-02-19Replacement Surface Sensor Insert
951-02-29Slim WTP Cell Container (nett)
951-02-30Slim WTP Cell Container Caps (nett)
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage supply108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Isocal-6 Range - Calisto 4953
Includes standard insert and 3 point traceable certificate
  
4953Calisto 4000 Series
 Temperature Range 30°C to 250°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
Metal Block Bath 
951-02-15Additional Standard Insert -2x4.5mm, 2x6.4mm, 1x8mm, 1x9.5mm x 157mm deep
951-02-15aBlank Insert
951-02-15cNon Standard Insert (consult Isotech)
951-06-07Alternative insert type B - 1x13mm,1x10mm, 1x8mm,1x5mm, 1x3.5mm x 157mm deep
951-06-08Alternative insert type C - 1x8mm, 6x6.5mm x 157mm deep
935-14-82/DBSemi Standard PRT - Temperature Range  -50°C to 250°C
935-14-75/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 250°C
Stirred Liquid Bath/Stirred Ice/Water Bath
951-06-01Stirred Liquid Container Kit
921-02-06Liquid in Glass Thermometer Support Kit 
Blackbody Source 
951-06-04Blackbody Target
Surface Sensor Calibrator
951-06-02Surface Sensor Calibrator Kit
ITS-90 Fixed Point Apparatus
17401 MSlim Gallium Melt Point Cell 
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
951-06-06C20 Silicon Oil (20°C to 200°C) 0.1L required
953-04-01VHT Silicon Oil (150°C to 250°C) 0.1L required
932-12-55Replacement Liquid Container Magnetic Follower (Qty 5)
935-14-83Replacement Surface Sensor Probe
951-02-19Replacement Surface Sensor Insert
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage supply108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Dry Block Calibrator - Jupiter 4852
Includes standard insert and 3 point traceable certificate
  
4852Jupiter 4000 Series
 Temperature Range 35°C to 660°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
Metal Block Bath
852-07-11Additional Standard Insert -2x4.5mm, 2x6.4mm, 1x8mm, 1x9.5mm x 140mm deep
852-07-07Blank Insert
852-07-07cNon Standard Insert (consult Isotech)
852-09-03Alternative insert type B - 1x13mm,1x10mm, 1x8mm,1x5mm, 1x3.5mm x 140mm deep
852-09-04Alternative insert type C - 1x8mm, 6x6.5mm x 140mm deep
935-14-72/DBSemi Standard PRT - Temperature Range -50°C to 670°C
935-14-79/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 660°C
Blackbody Source
852-09-05Blackbody Target Kit
Surface Sensor Calibrator
852-07-15Surface Sensor Calibrator Kit
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
853-04-02Rapid Air Cooling
935-14-118Replacement Surface Sensor/Black Body Probe
852-07-14Replacement Surface Sensor Insert
852-09-02Spare Insulation Pack for Black Body Source (nett)
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage supply100/120V – 50/60Hz (nett) additional cost
 200/240V – 50/60Hz






  


Dry Block Calibrator - Gemini 4857/550
Includes 3 point traceable certificate
  
4857/550Gemini 550/4000 Series
 Temperature Range 35°C to 550°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
935-14-72/DBSemi Standard PRT - Temperature Range -50°C to 670°C
935-14-79/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 660°C
  
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
Mixed Set of 4 Aluminium Sleeves - optional single hole per sleeve.  Specify from 4, 6, 8, 10, 12 or 14 x 150mm deep
857-07-01Set of 4 Aluminium Sleeves - blank
857-07-03One Aluminium Sleeve with 2 x 4.5mm x 150mm deep
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage supply100/120V – 50/60Hz 
 200/240V – 50/60Hz






  


Dry Block Calibrator - Gemini 4857/700
Includes 3 point traceable certificate
  
4857/700Gemini 700/4000 Series
 Temperature Range 50°C to 700°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
935-14-72/DBSemi Standard PRT - Temperature Range -50°C to 670°C (for use up to 650°C)
935-14-79/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 660°C
935-14-63Type N Thermocouple - Temperature Range 0°C to 1200°C  (for use up to 700°C)
  
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
Mixed Set of 4 Bronze Sleeves - optional single hole per sleeve.  Specify from 4, 6, 8, 10, 12 or 14 x 150mm deep
857-07-02Set of 4 Bronze Sleeves - blank
857-07-04One Bronze Sleeve with 2x4.5mm x 150mm deep
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage supply100/120V – 50/60Hz 
 200/240V – 50/60Hz






  


Dry Block Calibrator - Gemini  4857/550/LRI
Includes large removeable insert with 8 x 8mm pockets x 154mm deep and  3 point traceable certificate
  
4857/550/LRIGemini 550 LRI 4000 Series
 Temperature Range 35°C to 550°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
935-14-72/DBSemi Standard PRT - Temperature Range -50°C to 670°C 
935-14-79/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 660°C
  
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
976-07-01aAdditional Standard Removable Insert
976-07-01bBlank Insert
976-07-01cNon Standard Insert (consult Isotech)
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-112Carrying Case with wheels and pull out handle (nett)
  
Voltage supply100/120V – 50/60Hz 
 200/240V – 50/60Hz






  


Dry Block Calibrator - Gemini  4857/700/LRI 
Includes large removeable insert with 8 x 8mm pockets x 154mm deep and  3 point traceable certificate
  
4857/700/LRIGemini 700 LRI 4000 Series
 Temperature Range 50°C to 700°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
935-14-72/DBSemi Standard PRT - Temperature Range -50°C to 670°C (for use up to 650°C)
935-14-79/DB90° Angled Semi Standard PRT - Temperature Range -50°C to 660°C
935-14-63Type N Thermocouple - Temperature Range 0°C to 1200°C  (for use up to 700°C)
  
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories 
976-07-02aAdditional Standard Removable Insert
976-07-02bBlank Insert
976-07-02cNon Standard Insert (consult Isotech)
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-112Carrying Case with wheels and pull out handle (nett)
  
Voltage supply100/120V – 50/60Hz 
 200/240V – 50/60Hz






  


Portable Calibration Furnace - Pegasus 4853
Includes standard insert and 3 point traceable certificate
  
4853Pegasus 4000 Series
 Temperature Range 150°C to 1200°C
  
ADVANCEDwith Ethernet Interface and I-Cal Easy LOG Software
SITEwith Serial Communications and Cal Notepad Software
BASICwith Serial Communications and Cal Notepad Software
  
Metal Block Bath
853-06-01Additional Standard Insert - 4x8mm Pockets
853-06-02Blank Insert
853-06-02bNon Standard Insert (consult Isotech)
935-14-91Semi Standard Type R Thermocouple - Temperature Range 0°C to 1300°C
Blackbody Source
853-06-03Blackbody Target Kit (nett)
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (when ordered) (nett)
UKAS-SYST        ADVANCED ONLY5 point calibration for block temperature and reference probe (when ordered) and electrical simulation of indicator (nett)
UKAS-SIM            ADVANCED ONLY Calibration of input channels, electrical simulation only (nett)
Accessories
853-04-02Rapid Air Cooling
935-14-115Replacement Black Body Probe
970-05-01Spare Insulation Pack for Black Body Source (nett)
853-06-04Spare Insulation Pack for Metal Block Bath Insert (nett)
935-06-161Current Loop Adaptor (ADVANCED and Site only)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage supply100/120V – 50/60Hz 
 200/240V – 50/60Hz






  


Portable Calibration Furnace - Pegasus T Model 853T
Includes Semi-Standard Type R Thermocouple 935-14-91 type R thermocouple and 3 point traceable certificate
  
  
853TPegasus T
 Temperature Range 150°C to 1200°C
  
Voltage supply100/120V – 50/60Hz 
 200/240V – 50/60Hz
  
Accessories
853-02-31Standard Insert - 6 x 5mm pockets
853-02-30Blank Insert
843-02-30BNon Standard Insert (consult Isotech)
935-14-91Replacement Semi Standard Type R Thermocouple - Temperature Range 0°C to 1300°C
  
UKAS Calibration Option
UKAS-TEMP5 point calibration for block temperature and reference probe (nett)






  


Temperature Test Unit - Quick Cal Low Temperature
Includes 1 standard sleeve, 1 blank sleeve and 3 point traceable certificate
  
  
560Low Temperature Quick Cal
 Temperature Range -12°C to 140°C
  
Accessories 
560-06-01AAdditional Standard Sleeve with 1x6.8mm pocket x 120mm deep
560-06-01BBlank Sleeve
560-06-01CNon Standard Sleeve (consult Isotech)
935-14-98Semi-Standard PRT - Temperature Range -50°C to 350°C
935-42-14Rechargeable Battery (nett)
935-42-19Battery Charger (220/240V - 50/60HZ) (nett)
935-42-22Battery Charger (110/120V - 50/60HZ) (nett)
931-22-100Carrying Case (nett)
UKAS5 Point Comparison Calibration  (nett)
  
Voltage supplySwitch Mode Voltage Supply 100 to 240V - 50/60HZ
 Farenheit Operation Available






  


Temperature Test Unit - Quick Cal High Temperature
Includes standard insert and 3 point traceable certificate
  
  
550High Temperature Quick Cal
 Temperature Range 30°C to 350°C
  
Accessories 
550-06-01AAdditional Standard Insert with 1x8mm, 2x4.5mm and 2x6.5mm x 115mm deep
550-06-01BBlank Insert
550-06-01CNon Standard Insert (consult Isotech)
935-14-98Semi-Standard PRT - Temperature Range -50°C to 350°C
931-22-100Carrying Case (nett)
UKAS5 Point Comparison Calibration  (nett)
  
Voltage supply100/130V – 50/60Hz
 200/240V – 50/60Hz






  


Industrial Temperature Calibrators - Fast Cal
Include 3 point traceable certificate, Serial Communications, Cal Notepad Software and Carrying Case
  
907Fast-Cal HTM 2010 with Fixed Block of 3 x 4.5mm, 1 x 6.5mm and 1x8mm x 145mm deep
 Temperature Range -35°C to 140°C
 BASIC Version 
 COMPLETE with Semi Standard 935-14-82/DB
  
907Fast-Cal Low with standard insert 2x4.5mm, 1x6.5mm and 1x8mm x 140mm deep 
 Temperature Range -35°C to 140°C
 BASIC Version 
 COMPLETE with Semi Standard 935-14-82/DB
  
907Fast-Cal Medium with standard insert 2x4.5mm, 1x6.5mm and 1x8mm x 140mm deep
 Temperature Range 30°C to 350°C
 BASIC Version 
 COMPLETE with Semi Standard 935-14-98/DB
  
907Fast-Cal High with standard insert 2x4.5mm, 1x6.5mm and 1x8mm x 140mm deep
 Temperature Range 35°C to 650°C
 BASIC Version 
 COMPLETE with Semi Standard 935-14-72/DB
 COMPLETE with Semi Standard 935-14-63/DB
  
Acessories 
907-02-03Additional Standard Insert (Low and Medium)
907-02-03bBlank Insert (Low and Medium)
907-02-03cSpecial Insert (Low and Medium)
907-02-03dAdditional Standard Insert (High only)
907-02-03fBlank Insert (High only)
907-02-03gSpecial Insert (High only)
UKAS5 Point Comparison Calibration (nett)
  
Voltage supply100/130V – 50/60Hz
 200/240V – 50/60Hz






  


ITS-90 Isothermal Towers
Integrated ITS-90 Fixed Point Calibration System with Certificate of Purity and a Melt and Freeze Curve.  Serial Communications and Cal Notepad Software.
  
  
490Indium 156.5985°C
491Tin 231.928°C
492Zinc 419.527°C
493Aluminium 660.323°C
  
  
Special Package Price
Tin, Zinc and Aluminium systems when ordered together
 
  
Voltage supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
Calibration OptionUKAS Fixed Point Cell Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties






  


Slim Fixed Point Cells Sealed
99.9999% Pure.  With Certificate of Conformity
  
Quartz Clad Slim Fixed Point Cells
Require to be hand carried
17668 QSIndium 156.5985°C
17669 QSTin 231.928°C
17671 QSZinc 419.527°C
17672 QSAluminum 660.323°C
17673 QSSilver 961.78°C
17674 QSCopper 1084.62°C
  
Metal Clad Slim Fixed Point Cells
Transportable
17401 MGallium 29.7646°C
17724 MMercury -38.8344°C
17668 MLIndium 156.5985°C
17669 MLTin 231.928°C
17671 MLZinc 419.527°C
17672 MLAluminum 660.323°C
  
Accessories 
510-05-00Inconel basket including insulators for use with Medusa - Indium to Zinc (nett)
511-05-01Inconel basket including insulators for use with Medusa 511 - Aluminium (nett)
426-04-00Inconel basket including insulators for use with Oberon - Aluminium to Copper (nett)
  
Calibration OptionTraceable and UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hazardous               (consult Isotech)Due to the hazardous nature of Gallium and Mercury these cells are packed and shipped in accordance to IATA specification






  


Water Triple Point Cells
With Certificate of Conformity 
  
  
B8/30/130Temperature, 0.01°C
B12/40/210Temperature, 0.01°C
B12/46/210Temperature, 0.01°C
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties






  


Isocal-6 Range - Oceanus-6
Includes standard insert, 3 point traceable Certificate Serial Communications and Cal Notepad Software
  
580Oceanus-6Plus  
 Temperature Range 45°C below ambient to 140°C
  
 BASIC Version  
 SITE Version
  
Metal Block Bath
580-06-03Additional Standard Insert - 6x8mm x 250mm deep
580-06-04Blank Insert
580-06-05Non Standard Insert (consult Isotech)
580-06-06Adjustable Equalising Block - 6x8mm x 157mm deep
935-14-85/DBSemi Standard PRT - Temperature Range -50°C to 250°C
UKAS5 Point Comparison Calibration  (nett)
Stirred Liquid Bath/Stirred Ice/Water Bath
580-06-07Stirred Liquid Container for alcohol’s, water and oils
580-06-00Liquid in Glass Thermometer Support Kit
Blackbody Source 
580-02-12Blackbody Target
Surface Sensor Calibrator
580-06-08Surface Sensor Calibrator Kit 
ITS-90 Fixed Point Apparatus
17401Gallium Melt Point Cell & Support
B12/46/210Water Triple Point Cell & Supports
Accessories 
936-06-07C10 Oil (-35°C to 140°C) 1 Litre required
932-12-74Replacement Liquid Container Magnetic Follower (Qty 5)
935-14-114Replacement Surface Sensor Probe
580-02-11Replacement Surface Sensor Insert
580-06-01WTP Cell Support (nett)
580-06-02Gallium Cell Support (nett)
931-22-58Storage Case (nett)
  
Voltage supply100/130V – 50/60Hz
 200/240V – 50/60Hz






  


Dry Block Calibrator - Medusa 510 
Includes standard insert, 3 point traceable Certificate Serial Communications and Cal Notepad Software
  
510Medusa 510
 Temperature Range 30°C to 550°C
  
 BASIC Version
 SITE Version 
  
Metal Block Bath
510-06-01Additional Standard Insert - 6x8mm x 250mm deep
510-06-02Blank Insert
510-06-03Non Standard Insert (consult Isotech)
510-06-04Adjustable Equalising Block - 6 x 8mm holes x 157mm deep
935-14-95H/DBSemi Standard PRT - Temperature Range -80°C to 670°C
UKAS5 Point Comparison Calibration  (nett)
Blackbody Source
510-06-05Blackbody Target
Surface Sensor Calibrator
510-06-06Surface Sensor Calibrator Kit 
ITS-90 Fixed Point Apparatus - Metal Clad Slim Fixed Point Cells
Transportable 
17668 MLSlim Metal Clad Indium Fixed Point Cell
17669 MLSlim Metal Clad Tin Fixed Point Cell
17671 MLSlim Metal Clad Zinc Fixed Point Cell
ITS-90 Fixed Point Apparatus - Quartz Clad Slim Fixed Point Cells
Require to be hand carried 
17668 QSSlim Quartz Clad Indium Fixed Point Cell
17669 QSSlim Quartz Clad Tin Fixed Point Cell
17671 QSSlim Quartz Clad Zinc Fixed Point Cell
Accessories 
935-14-66Replacement Standard Thermocouple for BB Target
935-14-118Replacement Surface Sensor Probe
510-02-02Replacement Surface Sensor Calibrator Insert
510-05-00Slim Cell Holder including Insulators - Indium to Zinc (nett)
931-22-58Storage Case (nett)
  
Voltage supply100/130V – 50/60Hz
 200/240V – 50/60Hz






  


Dry Block Calibrator - Medusa 3 511
Includes standard insert, 3 point traceable Certificate Serial Communications and Cal Note Pad Software
  
  
511Medusa 3 511
 Temperature Range 50°C to 700°C
  
 BASIC Version
 SITE Version 
  
Metal Block Bath
511-06-01Additional Standard Insert - 6x8mm x 250mm deep
511-06-02Blank Insert
511-06-03Non Standard Insert (consult Isotech)
511-06-04Adjustable Equalising Block - 6x8mm x 157mm deep
935-14-95H/DBSemi Standard PRT - Temperature Range -80°C to 670°C
UKAS5 Point Comparison Calibration  (nett)
Blackbody Source
511-06-05Blackbody Target
Surface Sensor Calibrator
511-06-06Surface Sensor Calibrator Kit 
ITS-90 Fixed Point Apparatus - Metal Clad Slim Fixed Point Cells
Transportable 
17668 MLSlim Metal Clad Indium Fixed Point Cell
17669 MLSlim Metal Clad Tin Fixed Point Cell
17671 MLSlim Metal Clad Zinc Fixed Point Cell
17672 MLSlim Metal Clad Aluminium Fixed Point Cell
ITS-90 Fixed Point Apparatus - Quartz Clad Slim Fixed Point Cells
Require to be hand carried 
17668 QSSlim Quartz Clad Indium Fixed Point Cell
17669 QSSlim Quartz Clad Tin Fixed Point Cell
17671 QSSlim Quartz Clad Zinc Fixed Point Cell
17672 QSSlim Quartz Clad Aluminium Fixed Point Cell
Accessories 
935-14-66Replacement Standard Thermocouple for BB Target
935-14-118Replacement Surface Sensor Probe
510-02-02CReplacement Surface Sensor Calibrator Insert
510-05-00Slim Cell Holder including Insulators - Indium to Zinc (nett)
511-05-01Slim Cell Holder including Insulators - Aluminium (nett)
931-22-58Storage Case (nett)
  
Voltage supply100/130V – 50/60Hz
 200/240V – 50/60Hz






  


POTTS - Oberon
Includes Serial Communications and Cal Notepad Software
  
  
426Oberon POTTS
 Temperature Range 450°C to 1100°C
  
Voltage supply 110V – 50/60Hz only
  
Metal Block Bath
426-06-05Adjustable Equalising Block - 6x8mm x 160mm deep
  
ITS-90 Fixed Point Apparatus - Quartz Clad Slim Fixed Point Cells
Require to be hand carried 
17672 QSSlim Quartz Clad Aluminium Fixed Point Cell
17673 QSSlim Quartz Clad Silver Fixed Point Cell
17674 QSSlim Quartz Clad Copper Fixed Point Cell
  
Accessories 
426-04-00Inconel Cell Basket including Insulators - Aluminium to Copper - for use with Oberon (nett)
935-19-63Isolation Transformer to allow operation from 240V supply (nett)
935-19-71Isolation Transformer to allow operation from 220V supply (nett)
  
Calibration OptionUKAS Fixed Point Cell Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties






  


TTI-10 Handheld Thermometer 
Includes Cal Notepad Software for monitoring and logging, USB Cable, 2 Lemo Connectors to suit, protective rubber boot and traceable certificate
  
  
933TTI-10 Handheld Thermometer
 Temperature Range -200°C to 850°C
  
Semi Standard Pt100'sIncludes Probe Carrying Case and fitted Lemo Connector 
935-14-112/TTITemperature Range -50°C to 250°C
935-14-116/TTITemperature Range -100°C to 450°C
935-14-61/TTITemperature Range -50°C to 250°C
  
Accessories 
956Terminal Adaptor
931-22-101Carrying Case (nett)
  
UKAS System Calibration Package OptionThe following prices are for the UKAS System Calibration only - appropriate Semi-Standard must be selected at time of ordering
  
TTI-10-14-116/TTI4 Point System Calibration over the Temperature Range 0°C to 420°C (nett)
  
2nd 935-14-116/TTI Calibrated on Channel 2 at the same time and same points (nett)
  
TTI-10-14-61-SYST or TTI-10-14-1124 Point System Calibration over the Temperature Range       -50°C to 200°C (nett)
  
2nd935-14-61/TTI or 935-14-112/TTI Calibrated on Channel 2 at the same time and same points (nett)






  


milliK Precision Thermometer
Includes Cal Notepad Software for monitoring and logging, RS232 Cable, 2 Lemo Connectors to suit and traceable certificate
  
  
923milliK Precision Thermometer
 Temperature Range -270°C to 1820°C
Semi Standard     Pt100'sInclude Carrying Case and fitted Lemo Connector 
935-14-13/TTITemperature Range -196°C to 250°C
935-14-16/TTITemperature Range -100°C to 450°C
935-14-116/TTITemperature Range -100°C to 450°C
935-14-61/TTITemperature Range -50°C to 250°C
935-14-72/TTITemperature Range -50°C to 670°C
935-14-95H/TTITemperature Range -80°C to 670°C
935-14-95L/TTITemperature Range -200°C to 165°C
Working SPRT'sInclude Carrying Case and fitted Lemo Connector 
Metal Clad     909L/100Ω/TTITemperature Range -200°C to 165°C - Length 480mm 
Quartz Clad 909Q/100Ω/TTITemperature Range -200°C to 550°C - Length 480mm 
Accessories 
956Terminal Adaptor
931-22-102Carrying Case (nett)
Voltage supplyUniversal power supply allows operation from 90 to 240V 50/60Hz
  
SYSTEM CALIBRATION 
Only applicable when milliK and semi-standards Pt100 purchased at the same time
Temperature RangeCalibration Points/Typical Uncertainty
-196°C to 232°C-196°C (±0.030°C), -38.8°C (±0.015°C), 0.01°C  (±0.015°C), 156°C (±0.025°C),232°C (±0.025°C)
-196°C to 29.76°C-196°C (±0.030°C), -38.8°C (±0.015°C), 0.01°C (±0.015°C), 29.76°C (±0.015°C)
-50°C to 250°C-50°C (±0.025°C), 0.01°C (±0.015°C), 29.76°C (±0.015°C), 156°C (±0.025°C), 250°C (±0.030°C)
-80°C to 419°C-80°C (±0.030°C), -38.8°C  (±0.015°C), 0.01°C  (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C)
0.01°C to 419°C0.01°C (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C)
-80°C to 660°C-80°C (±0.030°C), -38.8°C (±0.015°C), 0.01°C  (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C), 660°C (±0.050°C)
0.01°C to 660°C0.01°C  (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C), 660°C (±0.050°C)
350°C to 1100°C350°C (±0.8°C), 600°C (±0.8°C), 850°C (±0.8°C), 1100°C (±0.8°C)
350°C to 1300°C350°C (±0.8°C), 700°C (±0.8°C), 1000°C (±0.8°C), 1300°C (±1.8°C)
ADDITIONAL SYSTEM CALIBRATION OPTIONS - Applicable when millik and semi-standard probe purchased at same time
Temperature RangeCalibration Points/Typical Uncertainty
0.01°C to 156°C0.01°C (0.01°C), 156°C (0.015°C)
-38°C to 29.7646°C-38°C (0.015°C), 0.01°C (0.01°C), 29.76°C (0.01°C)
*See Brochure - MILLIK HIGH ACCURACY TEMPERATURE MEASUREMENT 






  


millisKanner Channel Expander
Eight Channel Expansion Unit for milliK, maximum of four units per milliK
  
  
914amillisKanner Channel Expander (first unit)
 Includes following cables suitable for connecting milliK to millisKanner
932-42-33Universal Power Suply allows operation from 90 to 240V 50/60Hz (suitable to power up to 4 millisKanners)
914-03-02Digital Connecting Cable
914-02-02milliK to millisKanner linking cable
  
914bmillisKanner Channel Expander (subsequent)
 Includes following cables suitable for connecting millisKanner  to milliskanner
914-02-03DC Link Cable (Univeral PSU not required)
914-03-02Digital Connecting Cable
914-02-04millisKanner to millisKanner linking cable






  


True Temperature Indicator - TTI 22
Includes Cal Notepad Software for monitoring and logging, RS232 Cable and 2 Lemo Connectors to suit
  
  
926True Temperature Indicator TTI 22
 Temperature Range -250°C to 962°C
  
Selector Switch 
9548 Way Selector Switch for PRT's
  
Semi Standard Pt100'sInclude Carrying Case and Lemo Connector suitable for use with  TTI 22
935-14-13/TTIbTemperature Range -196°C to 250°C
935-14-16/TTIbTemperature Range -100°C to 450°C
935-14-61/TTIbTemperature Range -50°C to 250°C
935-14-72/TTIbTemperature Range -50°C to 670°C
935-14-95H/TTIbTemperature Range -80°C to 670°C
935-14-95L/TTIbTemperature Range -200°C to 165°C
  
Working SPRT'sInclude Carrying Case and Lemo Connector suitable for use with TTI 22
Metal Clad 909L/100Ω/TTIbTemperature Range -200°C to 165°C
Length 480mm
Quartz Clad 909Q/100Ω/TTIb Temperature Range -200°C to 550°C
Length 480mm
  
Accessories 
956/TTI22Terminal Adaptor
931-22-106Carrying Case (nett)
  
Voltage supplyUniversal power supply allows operation from 90 to 240v 50/60 Hz
  
Calibration OptionUKAS Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties






  


Terminal Adaptor - Model 956
Simple Accessory providing 4mm terminal posts for the connection of bare wires, spade terminals or 4mm plugs
  
  
956Terminal Adaptor for use with TTI 7/TTI 6
956/TTI 22Terminal Adaptor for use with TTI 22






  


Miniature Fixed Resistor - Model 836
Precise and Stable for Industrial References
  
  
836FRM 10Ω
836FRM 25Ω
836FRM 100Ω
836FRM 1,000Ω
836FRM 10,000Ω
  
  
Calibration OptionUKAS Calibration available refer to Calibration Price List 






  


Selector Switch - 8 Way
Use with I-Cal Software
  
  
9548 Way Selector Switch for PRT's
9588 Way Selector Switch for T/C's
  
  
Voltage supplySwitch Mode voltage supply 100 to 250V






  


Surface Measurement - Model 944
Includes Semi-Standard Thermocouple 935-14-81
  
  
944Model 944
 Temperature Range 30°C to 350°C
  
Voltage supply100/120V – 50/60Hz
 200/240V – 50/60Hz
Accessories 
935-14-81Replacement Semi Standard Thermocouple 
 When a replacement 935-14-81 is purchased the 944 must be returned to Isotech
  
Calibration Option5 Point Traceable Calibration (nett)






  


Surface Sensor Calibrator - Small Hot Plate
 
  
  
983Small Hot Plate
 Temperature Range 35°C to 350°C
  
Voltage supply100/115V – 50/60Hz
 200/230V – 50/60Hz






  


Reference Probes - Semi Standard Platinum Resistance Thermometers
Includes carrying case
  
  
935-14-112Temperature Range -50°C to 250°C 
935-14-13Temperature Range -196°C to 250°C
935-14-113Temperature Range -100°C to 250°C
935-14-16Temperature Range -100°C to 450°C
935-14-116Temperature Range -100°C to 450°C
935-14-61Temperature Range -50°C to 250°C
935-14-72Temperature Range -50°C to 670°C
935-14-82Temperature Range -50°C to 250°C
935-14-85Temperature Range -50°C to 250°C
935-14-95HTemperature Range -80°C to 670°C
935-14-95LTemperature Range -200°C to 165°C
935-14-98Temperature Range -50°C to 350°C
  
Calibration OptionUKAS Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Reference Probes - 90° Angled Semi Standard Platinum Resistance Thermometers
Includes carrying case
  
935-14-75Temperature Range -50°C to 250°C
935-14-79Temperature Range 0°C to 660°C
  
Calibration OptionUKAS Calibration available with Dry Block Calibrators refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Termination Options - Example 935-14-61/BW; 935-14-75/DB
  
BWBare Wire will be supplied unless otherwise specified
TTILemo Connector to suit TTI 1 to TTI10 (nett)
TTIbLemo Connector to suit TTI 22 (nett)
DBConnector for Dry Block Calibrator Model (nett)






  


Reference Probes - Semi Standards Thermocouples 
 
  
Temperature Range 0°C to 1300°C
935-14-91/R/300Type R - Length 300mm, Includes Carrying Case
935-14-91/S/300Type S - Length 300mm, Includes Carrying Case
935-14-88/R/300Type R - Length 300mm, Includes Carrying Case
935-14-88/S/300Type S - Length 300mm, Includes Carrying Case
  
Temperature Range 0°C to 1200°C
935-14-63/N/300Type N - Length 300mm
935-14-64/N/300Type N - Length 300mm
935-14-65/N/300Type N - Length 300mm
935-14-66/N/500Type N - Length 500mm
935-14-67/N/500Type N - Length 500mm
935-14-68/N/500Type N - Length 500mm
  
931-22-38Carrying Case (nett)
  
Calibration OptionUKAS Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties






  


Calibration Software 
 
  
  
Cal NotepadPermits connection of both an indicator and the calibration bath, view data on configurable chart displays, log data to file and control the bath
  
I Cal EasyCan automatically calibrate up to 20 temperature sensors, calculate coefficients and print own design certificates
  
I Cal Easy PlusCan automatically calibrate up to 20 temperature sensors, calculate coefficients and print own design certificates. Includes additional drivers for third party instruments.  Before ordering consult Isotech.






  


Blackbody Sources - Blackbody Fixed Point Cells 
Includes Certificate of Metal Analysis
  
  
Primary Standard Cells suitable for Medusa R
998-06-00AIndium - Temperature Range 156.60°C
998-06-00BTin - Temperature Range 231.93°C
998-06-00CZinc - Temperature Range 419.53°C
  
Primary Standard Cells suitable for Oberon R
998-06-00D*Aluminium - Temperature Range 660.32°C
998-06-00E*Silver - Temperature Range 961.78°C
998-06-00G*Copper - Temperature Range 1084.62°C
  
Medium Temperature "Hockey Puck" Cells suitable for Gemini R
431-03-00Gallium - Temperature Range 29.7646°C (special to order)
976-05-00AIndium - Temperature Range 156.60°C
976-05-00BTin - Temperature Range 231.93°C
976-05-00CZinc - Temperature Range 419.53°C
  
Medium Temperature "Hockey Puck" Cells suitable for Hyperion R
982-05-01Gallium - Temperature Range 29.7646°C 
  
High Temperature Cells suitable for Pegasus R
970-06-00AIndium - Temperature Range 156.60°C
970-06-00BTin - Temperature Range 231.93°C
970-06-00CZinc - Temperature Range 419.53°C
970-06-00D*Aluminium - Temperature Range 660.32°C
970-06-00E*Silver - Temperature Range 961.78°C
  
Hazardous               (consult Isotech)Due to the hazardous nature of the Gallium, the cells are packed and shipped in accordance with IATA specifications
  
 * These cells are required to be surrounded by gas for protection at high temperatures - see Model 984






  


Gas Flow System - Model 984
Supplied with external power supply, 2 x connecting pipes and fittings
  
  
984Gas Flow System






  


Blackbody Source - Hyperion R
Low Temperature Primary Source.  50mm diameter cavity, 0.995 emissivity.  Includes 935-14-113/DB, Serial Communications and Cal Notepad Software.   
  
  
982Hyperion R
 Temperature Range -20°C to 125°C
  
Hockey Puck Cells 
982-05-01Gallium - Temperature Range 29.7646°C (special to order)
  
Voltage supply100/130V – 50/60Hz
 208/240V – 50/60Hz
  
Accessories 
812-01-06Set of 4 Orifice Plates to restrict cavity (40,30,20,10mm)
935-14-113/DBReplacement Semi-Standard Probe  -100°C to 250°C
  
UKAS Calibration Option5 Point Calibration calibrating the units inbuilt indicator and supplied 935-14-113/DB against an Isotech laboratory contact thermometer (nett)
  
Hazardous               (consult Isotech)Due to the hazardous nature of the Gallium, the cells are packed and shipped in accordance with IATA specifications






  


Blackbody Source - Gemini R 550
Medium Temperature Primary Source.  65mm diameter cavity, 0.995 emissivity. Includes 935-14-72/DB, Serial Communications and Cal Notepad Software.   
  
  
976Gemini R 550
 Temperature Range 30°C - 550°C
  
Voltage supply100/130V – 50/60Hz
 208/240V – 50/60Hz
  
Hockey Puck Cells 
431-03-00Gallium - Temperature Range 29.7646°C (special to order)
976-05-00AIndium - Temperature Range 156.60°C
976-05-00BTin - Temperature Range 231.93°C
976-05-00CZinc - Temperature Range 419.53°C
  
Accessories 
976-01-05Set of 5 Orifice Plates to restrict cavity (50,40,30,20,10mm)
935-14-72/DBReplacement Semi-Standard Probe -50°C to 670°C
984Gas Flow System
  
UKAS Calibration Option5 Point Calibration calibrating the units inbuilt indicator and supplied 935-14-72/DB against an Isotech laboratory contact thermometer (nett)
  
Hazardous               (consult Isotech)Due to the hazardous nature of the Gallium, the cells are packed and shipped in accordance with IATA specifications






  


Blackbody Source - Pegasus R
High Temperature Primary Source. 20mm diameter cavity, 0.995 emissivity.  Includes 935-14-115, Serial Communications and Cal Notepad Software.   
  
  
970Pegasus R
 Temperature Range 150°C - 1200°C
  
Voltage supply100/130V – 50/60Hz
 208/240V – 50/60Hz
  
High Temperature Cells 
970-06-00AIndium - Temperature Range 156.60°C
970-06-00BTin - Temperature Range 231.93°C
970-06-00CZinc - Temperature Range 419.53°C
970-06-00D*Aluminium - Temperature Range 660.32°C
970-06-00E*Silver - Temperature Range 961.78°C
  
Accessories 
935-14-115Replacement Semi-Standard Probe 
970-05-01Spare Insulation Pack for Blackbody Source (nett)
984Gas Flow System
  
UKAS Calibration Option5 Point Calibration calibrating the units inbuilt indicator and supplied 935-14-115 against an Isotech laboratory contact thermometer (nett)
  
  
 * These cells are required to be surrounded by gas for protection at high temperatures - see Model 984






  


Blackbody Source - Medusa R
Medium Temperature Primary Source.  45mm diameter cavity, 0.995 emissivity. Includes 935-14-95H, Serial Communications and Cal Notepad Software.   
  
  
999Medusa R
 Temperature Range 30°C - 550°C
  
Voltage supply100/130V – 50/60Hz
 208/240V – 50/60Hz
  
Primary Standard Cells
998-06-00AIndium - Temperature Range 156.60°C
998-06-00BTin - Temperature Range 231.93°C
998-06-00CZinc - Temperature Range 419.53°C
  
Accessories  
935-14-95H/DBReplacement Semi-Standard Probe   -80°C to 670°C
984Gas Flow System
  
Calibration OptionUKAS Calibration available on request






  


Blackbody Source - Oberon R
High Temperature Primary Source. 50mm diameter cavity, 0.995 emissivity. Includes Serial Communications and Cal Notepad Software.   
  
  
426Oberon R
 Temperature Range 450°C - 1100°C
  
Voltage supply100V – 50/60Hz
  
Primary Standard Cells 
998-06-00D*Aluminium - Temperature Range 660.32°C
998-06-00E*Silver - Temperature Range 961.78°C
998-06-00G*Copper - Temperature Range 1084.62°C
  
Accessories  
935-19-63Isolation Transformer to allow operation from 240V supply (nett)
935-19-71Isolation Transformer to allow operation from 220V supply (nett)
984Gas Flow System
  
Calibration OptionUKAS Calibration available on request
  
 * These cells are required to be surrounded by gas for protection at high temperatures - see Model 984






  


Blackbody Source - Cyclops
BB Source 878-01 with thermocouple access hole at 90° to main aperture.  Includes 935-14-131 Type R Control Thermocouple, Serial Communications and Cal Notepad Software.
  
  
878Cyclops
 Temperature Range 100°C to 1300°C
  
Voltage supply208/240V – 50/60Hz
 100/130V – 50/60Hz 
  
Aperture Hole45mm aperture hole (please specify)
 17mm aperture hole  (please specify)
  
Special to orderBB Source 878-01A with thermocouple access hole at rear - in view from aperture (please specify)
  
Accessories 
878-02-08Standard Equalising Block - 4 x 8mm x 4 x 6mm i.d. - 180mm leg length 
878-01Replacement BB Source with thermocouple access hole at 90° to main aperture - hidden from aperture view
878-01AReplacement BB Source with thermocouple access hole at rear - in view from aperture
935-14-130Control Thermocouple for use with equalising block or standard for Blackbody Source
935-14-131Replacement Control Thermocouple Type R






  


Blackbody Source - Model 988
Includes 3 point traceable certificate
  
  
988Thermal Image and Infrared Calibration Source 
 Temperature Range 20°C to 45°C
  
Voltage supplySwitch Mode Power Supply supplied as standard
 100-240VAC
  
Calibration OptionTraceable 3 Point Re-Calibration (nett)






  


Blackbody Source - Model 989
Includes 3 point traceable certificate
  
  
989Thermal Image and Infrared Calibration Source 
 Temperature Range 20°C to 50°C
  
 Quantity 1 off
 Quantity 2 to 4 off
 Quantity 5 to 25 off
  
Voltage supplySwitch Mode Power Supply supplied as standard
 100-240VAC
  
Calibration OptionTraceable 3 Point Re-Calibration (nett)
  
Accessories 
935-16-112RS422 to RS232 Converter Lead (nett)
989/02Short Extension Tube - 40mm (nett)
989/03Long Extension Tube - 210mm (nett)
  
Semi-Standard PRT 
935-14-82/BWSemi Standard PRT - Temperature Range -50°C to 250°C
UKAS3 Point calibration of 935-14-82/BW (nett)
  
Calibration Kit 989/01Comprising of…
TTI-10 Handheld Thermometer
 935-14-82/TTI Semi Standard PRT - Temperature        Range -50°C to 250°C
 3 Point System Calibration of TTI-10 + 935-14-82/TTI  over the range 0°C to 50°C, uncertainty 0.02°C (20mK)  (nett)






  


Greybody Source - Model 975
Portable, lightweight temperature source
  
  
975Greybody Source
 Temperature Range 50°C to 350°C
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz






  


Blackbody Source - QuickCal Blackbody
For rapid and portable checking of infrared thermometers
  
  
550-02Quick-Cal Blackbody
 Temperature Range 30°C to 350°C
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz
 Farhenheit operation available
Accessories 
931-22-100Carrying Case (nett)
  
Calibration OptionTraceable 5 Point Re-Calibration (nett)






  


Thermocouple Probes - Cold Junction
Mulit-Junction Probes for Compensation Units.  Standard Length 1 Meter.
  
  
880 SSingle Junction (per thermocouple type)
880 DDouble Junction (per thermocouple type)
  
On ordering please advise the following
  
SpecifyNumber of Junctions Required
Select from Thermocouple TypeK, T, J, E,N, U (compensating for Type R or S unless otherwise specified)
Noble MetalType R or S (additional cost - consult Isotech)
AdviseLength of Probe required (L1)
 Length of Lead required (L2)
 Maxiumum Probe Diameter
For use withie, Zeref…..
  
Additional lengthPer meter (nett)
  
  
UKAS Calibration Option880 Calibration 1st Junction (nett)
 Subsequent Junctions when calibrated at the same time  (nett per junction)






  


Thermocouple Reference Unit - TRU Model 938
References up to 100 thermocouples.  Thermocouples not included.
Normally uniquely specified for each order.  Before ordering please consult Isotech.
  
  
938/36TRU 938/36 
 For up to 36 thermocouples
 Temperature Range 0°C (or 45°C to 70°C)
 (B1) 6 pockets x 6.2mm plus 1 x 4.2mm standard probe pocket x 130mm deep
  
938/100TRU 938/100 
 For up to 100 thermocouples
 Temperature Range 0°C (or 45°C to 70°C)
 (B2) 8 pockets x 8.2mm plus 1 x 4.2mm standard probe pocket x 76mm
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz
  
Accessories 
935-14-54Optional PRT to suit block (B1). Includes UKAS Calibration at 0.01°C
935-14-55Optional PRT to suit block (B2). Includes UKAS Calibration at 0.01°C
935-17-32Fan Filter
  
 The alarm is a single pole relay, not a change over contact.  Default setting is open at set temperature, closed when the temperature deviates by ±0.2°C from 0°C.  For alarm contacts closed at 0°C and opening on alarm please specify.






  


Thermocouple Reference Unit - TRU Model 937
References up to 100 thermocouples.  Thermocouples not included.
Normally uniquely specified for each order.  Before ordering please consult Isotech.
  
  
937/50TRU 937/50 
 For up to 50 thermocouples
 Temperature Range 0°C (or 45°C to 70°C)
 (B2) 8 pockets x 8.2mm plus 1 x 4.2mm standard probe pocket x 76mm
  
937/100TRU 937/100 
 For up to 100 thermocouples
 Temperature Range 0°C (or 45°C to 70°C)
 (B2) 8 pockets x 8.2mm plus 1 x 4.2mm standard probe pocket x 76mm
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz
  
Accessories 
935-14-55Optionally fitted PRT to suit block (B2).   Includes UKAS Calibration at 0.01°C
935-17-32Fan Filter
  
Specify Thermocouple type and quantityDouble Junction Thermocouples include input and output screw terminal connectors (Klippon)
  
Select from Thermocouple TypeK, T, J, E,N, U (compensating for Type R or S unless otherwise specified) (per thermocouple type)
Noble MetalType R or S (additional cost - consult Isotech)
SpecifyNumber of Junctions Required
  
 The alarm is a single pole relay, not a change over contact.  Default setting is open at set temperature, closed when the temperature deviates by ±0.2°C from 0°C.  For alarm contacts closed at 0°C and opening on alarm please specify.






  


Thermocouple Reference Unit - TRUrac Model 847
References up to 100 thermocouples.  Thermocouples not included.
Normally uniquely specified for each order.  Before ordering please consult Isotech.
  
  
847TRUrac 847 
 For up to 100 thermocouples
 Temperature Range 0°C (or 45°C to 70°C)
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz
  
Accessories 
935-14-54Optionally fitted PRT to suit block (B2). Includes UKAS Calibration at 0.01°C
935-17-32Fan Filter
 Encased Unit
  
Specify Thermocouple type and quantityDouble Junction Thermocouples includes input and output screw terminal connectors (Klippon)
  
Select Thermocouple TypeK, T, J, E, U, N (U compensating for type R and S unless otherwise specified) (per thermocouple type)
Noble MetalType R or S (additional cost - consult Isotech)
SpecifyNumber of Junctions Required
  
 The alarm is a single pole relay, not a change over contact.  Default setting is open at set temperature, closed when the temperature deviates by ±0.2°C from 0°C.  For alarm contacts closed at 0°C and opening on alarm please specify.






  


Thermocouple Reference Unit - Hotbox Model 830
References up to 200 thermocouples.  Thermocouples not included.
Normally uniquely specified for each order.  Before ordering please consult Isotech.
  
  
830Hotbox 830 
 For up to 200 thermocouples
 Temperature Range 45°C to 70°C
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz
  
Accessories 
935-14-08Optionally fitted PRT to suit block. Includes UKAS Calibration at 0.01°C
935-14-08Optionally fitted PRT to suit block. Includes UKAS Calibration at 0.01°C, 50°C and 75°C
  
Specify Thermocouple type and quantityDouble Junction Thermocouples includes input and output screw terminal connectors (Klippon)
  
Select Thermocouple TypeK, T, J, E, U, N (U compensating for type R and S unless otherwise specified) (per thermocouple type)
Noble MetalType R or S (additional cost - consult Isotech)
SpecifyNumber of Junctions Required






  


Thermocouple Reference Unit - Isobox Model 842
References up to 100 thermocouples.  Thermocouples not included.
Normally uniquely specified for each order.  Before ordering please consult Isotech.
  
  
842Isobox 842 
 For up to 100 thermocouples
 Temperature Range -20°C to 70°C
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz
 24VDC
 Other special to order (consult Isotech)
  
Accessories 
935-14-08Optionally fitted PRT to suit block. Includes UKAS Calibration at 0.01°C
  
Specify block sensor type
Type of isothermal block sensor - maximum 4, 1 included as standard
  
Select Thermocouple TypeK, T, J, E, U, N (U compensating for type R and S unless otherwise specified)
  
Specify Thermocouple type and quantityDouble Junction Thermocouples includes input and output screw terminal connectors (Klippon)
  
Select Thermocouple TypeK, T, J, E, U, N (U compensating for type R and S unless otherwise specified) (per thermocouple type)
Noble MetalType R or S (additional cost - consult Isotech)
SpecifyNumber of Junctions Required






  


Thermocouple Reference Unit - ISOrac Model 844
References up to 100 thermocouples. Thermocouples not included.
Normally uniquely specified for each order.  Before ordering please consult Isotech.
  
  
844/50Isorac 844/50
 For up to 50 thermocouples
 Temperature Range -20°C to 70°C
  
844/100Isorac 844/100
 For up to 100 thermocouples
 Temperature Range -20°C to 70°C
  
Voltage supply100/130V – 50/60Hz 
 208/240V – 50/60Hz
 24VDC
 Other special to order (consult Isotech)
  
Accessories 
935-14-08Optionally fitted PRT to suit block. Includes UKAS Calibration at 0.01°C
  
Specify block sensor type
Type of isothermal block sensor - maximum 4, 1 included as standard
  
Select Thermocouple TypeK, T, J, E, U, N (U compensating for type R and S unless otherwise specified)
  
Specify Thermocouple type and quantityDouble Junction Thermocouples include input and output screw terminal connectors (Klippon)
  
Select Thermocouple TypeK, T, J, E, U, N (U compensating for type R and S unless otherwise specified) (per thermocouple type)
Noble MetalType R or S (additional cost - consult Isotech)
SpecifyNumber of Junctions Required




Jarrett-Isotech Range Water Triple Point Cells                                          
With Certificate of Conformity 
  
Borosilicate  
A11/50/270Temperature, 0.01°C
A13/50/270Temperature, 0.01°C
B11/50/270Temperature, 0.01°C
B11/65/270Temperature, 0.01°C
B13/65/270Temperature, 0.01°C
B16/65/270Temperature, 0.01°C
  
Quartz 
A11/50/270QTemperature, 0.01°C
B11/50/270QTemperature, 0.01°C
B11/65/270QTemperature, 0.01°C
  
Isotech Water Triple Point Cells
With Certificate of Conformity 
  
B8/30/130Temperature, 0.01°C
B12/40/210Temperature, 0.01°C
B12/46/210Temperature, 0.01°C
  
Calibration OptionTraceable and UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties






  


Maintenance Bath Water Triple Point
For the maintenance of 1 to 4 Water Triple Point Cells
  
  
18233Water Triple Point Maintenance Bath
 Temperature Range 0.01°C
  
Voltage Supply 100/130V – 50/60Hz
 208/240V – 50/60Hz
  
  
SpecifyPlease specify which type of Triple Point of Water Cell will be used so that we can supply the correct cell holder






  


Ice Mantle Maker Water Triple Point
For use with Large Water Triple Point Cells. Includes 1 x Ice Bridge Prevention Collar
  
  
452Ice Mantle Maker
  
Accessories 
451-01-04Additional Ice Bridge Prevention Collar
  
  
SpecifyIce Bridge Prevention Collars are manufactured to suit the cell in use, please specify the following:
  
 Cell Type
 Outside Diameter of Water Triple Point Cell (mm)
 Depth from shoulder of Cell to water level (mm)






  


Sostmann-Isotech Gallium Cell Sealed
Includes Certificate of Conformity 
  
  
17401Sostmann-Isotech Gallium Cell
 Temperature Range 29.7646°C
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
Hazardous
(consult Isotech)
Due to the hazardous nature of the Gallium, the cells are packed and shipped in accordance with IATA specifications






  


Apparatus Gallium 
For the realization and maintenance of the Gallium Cell automatically
  
  
17402BGallium Apparatus 
 Temperature Range 29.7646°C
  
Voltage Supply 100/130V – 50/60Hz
 208/240V – 50/60Hz






  


Isotech Mercury Cell  
Includes Certificate of Conformity 
  
  
17724Mercury Triple Point Cell 
 Temperature Range -38.8344°C
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
Hazardous
(consult Isotech)
Due to the hazardous nature of the Mercury the cells are packed and shipped in accordance with IATA specifications






  


Apparatus Mercury Triple Point Model
A cryostat to realise the Triple Point of Mercury
  
  
17725Mercury Triple Point Apparatus
 Temperature Range -36°C to -42°C
  
Voltage Supply  208/240V – 50Hz
  208/240V – 60Hz






  


Triple Point Apparatus Simple Argon
For the realisation of the Argon Triple Point 
  
471Triple Point Apparatus Simple Argon
 Temperature Range -189.3442°C
  
  
  
Hazardous
(consult Isotech)
Due to the hazardous nature of the Argon the apparatus is packed and shipped in accordance with IATA specifications






  


Fixed Point Cells Optimal - SEALED
99.9999% Pure.  Includes Certificate of Conformity
  
QUARTZ Clad Sealed Fixed Point Cells
Require to be hand carried 
17668Indium 156.5985°C
17669Tin 231.928°C
17671Zinc 419.527°C
17672Aluminum 660.323°C
17673Silver 961.78°C
17674Copper 1084.62°C
  
METAL Clad Sealed Fixed Point Cells 
Transportable 
17668MOIndium 156.5985°C
17669MOTin 231.928°C
17671MOZinc 419.527°C
17672MOAluminum 660.323°C
  
AccessoriesBasket and heat shunts are required for the cells when used with Isotech Furnaces
Basket Assemblies for Isotech furnaces (excluding 465)
410-07-01 Type BOptimal Cell Basket Assembly  - Indium, Tin (nett)
410-07-01 Type BOptimal Cell Basket Assembly - Zinc (nett)
410-07-01 Type BOptimal Cell Basket Assembly - Aluminium, Silver, Copper (nett)
Basket Assemblies for Isotech 465 only
465-04-02Optimal Cell Basket Assembly for Tin and Zinc (nett)
465-04-01Optimal Cell Basket Assembly - Aluminium, Silver, Copper (nett)
 
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hand Carry RecommendationQuartz Cells require to be hand carried however due to hand carry restrictions imposed by the airlines this may not be possible.  For more information regarding hand carry please consult with Isotech.






  


Fixed Point Cells Optimal - OPEN
99.9999% Pure.  Includes Certificate of Conformity
  
QUARTZ Open Fixed Point Cell 
Transportable 
17668QCOIndium 156.5985°C
17669QCOTin 231.928°C
17671QCOZinc 419.527°C
17672QCOAluminum 660.323°C
17673QCOSilver 961.78°C
17674QCOCopper 1084.62°C
  
For Quartz Open Fixed Point Cells only please specify length required 
  
Design type ACrucible Length 460mm ±2mm
 Re-Entrant Length 450mm ±2mm
Design type BCrucible Length 520mm ±2mm
 Re-Entrant Length 510mm ±2mm
Design type CCrucible Length 620mm ±2mm
 Re-Entrant Length 610mm ±2mm
  
METAL Open Fixed Point Cell 
Transportable 
17668MCOIndium 156.5985°C
17669MCOTin 231.928°C
17671MCOZinc 419.527°C
17672MCOAluminum 660.323°C
  
Sostmann-Isotech Gallium Cell
99.99999% Pure. Includes Certificate of Conformity
  
METAL Open Fixed Point Cell 
17401 (0)Sostmann-Isotech Gallium Cell 29.7646°C
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hazardous
(consult Isotech)
Due to the hazardous nature of the Gallium the cells are packed and shipped in accordance with IATA specifications






  


Furnaces - Dual 
For operation from Indium to Copper Fixed Points
Includes 425-06-01 gantry holder for thermometers
  
  
17707Low Temperature Dual Furnace
 Temperature Range 125°C to 250°C
 For Indium and Tin Fixed Points
  
Voltage Supply 108/115V – 50/60Hz
 208/240V – 50/60Hz
  
17706High Temperature Dual Furnace
 Temperature Range 400°C to 1000°C
 For Zinc, Aluminium and Silver Fixed Points
  
Voltage Supply 110V – 50/60Hz 
 230V – 50/60Hz 
  
17705Very High Temperature Dual Furnace
 Temperature Range 500°C to 1090°C
 For Aluminium, Silver and Copper Fixed Points
  
Voltage Supply 110V – 50/60Hz 
 230V – 50/60Hz
  
Accessories 
420-02-15Inconel Equalising Block (17705, 17706)
410-02-18Aluminium Equalising Block (17707)
824-01-00Fan Assembly to cool thermometer handle
425-06-01Gantry Holder for Thermometers






  


Furnaces - Heat Pipe 
For operation from Indium to Copper Fixed Points
Includes 425-06-01 gantry holder for thermometers
  
  
17702WLow Temperature Heat Pipe Furnace
 Temperature Range 125°C to 250°C
 For Indium and Tin Fixed Points
  
Voltage Supply 108/115V – 50/60Hz
 208/240V – 50/60Hz
  
17702PHigh Temperature Heat Pipe Furnace
 Temperature Range 400°C to 1000°C
 For Zinc, Aluminium and Silver Fixed Points
  
Voltage Supply 110V – 50/60Hz 
 230V – 50/60Hz 
  
17702SVery High Temperature Heat Pipe Furnace
 Temperature Range 500°C to 1090°C
 For Aluminium, Silver and Copper Fixed Points
  
Voltage Supply 110V – 50/60Hz
 230V – 50/60Hz 
  
Accessories 
420-02-15Inconel Equalising Block (17702P, 17702S)
410-02-18Alunimium Equalising Block (17702W)
824-01-00Fan Assembly to cool thermometer handle
411-01-11BAnnealing Adaptor
425-06-01Gantry Holder for Thermometers






  


Furnaces - Low Temperature 
For Indium, Tin and Zinc Fixed Points 
Includes 425-06-01 gantry holder for thermometers 
  
  
17701Low Temperature Furnace Model 
 Temperature Range 50°C to 500°C
  
Accessories 
824-01-00Fan Assembly to cool thermometer handle
411-01-11Annealing Adaptor
425-06-01Gantry Holder for Thermometers
  
Voltage Supply 108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Furnaces - Medium Temperature 
For Indium, Tin, Zinc and Aluminium Fixed Points
Includes 425-06-01 gantry holder for thermometers 
  
  
17703Medium Temperature Furnace Model 
 Temperature Range 50°C to 700°C
  
Accessories 
824-01-00Fan Assembly to cool thermometer handle
411-01-11BAnnealing Adaptor
420-02-14Aluminium Bronze Equalising Block
425-06-01Gantry Holder for Thermometers
  
Voltage Supply 108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Furnaces - 3 Zone High Temperature 
For Zinc, Aluminium, Silver, Gold and Copper Fixed Points
Includes 425-06-01 gantry holder for thermometers 
  
  
4653 Zone High Temperature Furnace 
 Temperature Range 250°C to 1200°C
  
Voltage Supply 108/130V – 50/60Hz
 208/240V – 50/60Hz
  
AccessoriesBasket and heat shunts are required for the cells when used with Isotech Furnaces
465-04-02Optimal Cell Basket Assembly for Tin and Zinc (nett)
465-04-01Optimal Cell Basket Assembly for Aluminium, Silver and Copper (nett)
465-02-06Ceramic Equalising Block 
425-06-01Gantry Holder for Thermometers






  


Furnaces - Annealing  
For the pre-warming, annealing and cool down of SPRTS
  
  
414Annealing Furnace
 Ambient to 1000°C with single ramp to set point
  
Voltage Supply 110V – 50/60Hz 
 240V – 50/60Hz 






  


Primary SPRT - 670/25.5Ω 
Includes traceable certificate at Rtpw and Wga and carrying case
  
Quartz 
670SQ/25.5ΩTemperature Range -200°C to 670°C
 Length 480mm
 Length 650mm
Metal  
670SH/25.5ΩTemperature Range -80°C to 670°C
 Length 480mm
 Length 650mm
Metal  
670SL/25.5ΩTemperature Range -200°C to 165°C
 Length 480mm
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hand Carry RecommendationWe recommend that these thermometers are hand carried where possible
  
  
Model 992 SPRT Extension Lead 
For Isotech SPRTS, includes LEMO connector 
  
  
992Standard Length 10M
  
Additional Lengthper meter 
  
NoteOn ordering an 992 extension lead at the same time as an SPRT the LEMO connector will be fitted to the SPRT.






  


Primary SPRT - 96178/0.25Ω 
Includes traceable certificate at Rtpw and Wga and carrying case
  
Quartz 
 96178/0.25ΩTemperature Range 0°C to 1000°C
 Length 650mm
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hand Carry RecommendationWe recommend that these thermometers are hand carried where possible
  
  
Model 992 SPRT Extension Lead 
For Isotech SPRTS, includes LEMO connector 
  
  
992Standard Length 10M
  
Additional Lengthper meter 
  
NoteOn ordering an 992 extension lead at the same time as an SPRT the LEMO connector will be fitted to the SPRT.






  


Copper Point SPRT Model 108462
Includes traceable certificate at Rtpw and Wga and carrying case
  
  
Model 108462Temperature Range 0°C to 1100°C
 Length 650mm
 Includes 416 Protection Device
  
  
Model 992 SPRT Extension Lead 
For Isotech SPRTS, includes LEMO connector 
  
  
992Standard Length 10M
  
Additional Lengthper meter 
  
NoteOn ordering an 992 extension lead at the same time as an SPRT the LEMO connector will be fitted to the SPRT.






  


Working SPRT - 909/25.5Ω 
Includes traceable certificate at Rtpw and Wga and carrying case
  
Quartz 
909Q/25.5ΩTemperature Range -200°C to 670°C
 Length 480mm
 Length 550mm
 Length 600mm
Metal  
909H/25.5ΩTemperature Range -80°C to 670°C
 Length 480mm
 Length 550mm
 Length 600mm
Metal  
909L/25.5ΩTemperature Range -200°C to 165°C
 Length 480mm
 Length 550mm
 Length 600mm
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hand Carry RecommendationWe recommend that these thermometers are hand carried where possible
  
  
Model 992 SPRT Extension Lead 
For Isotech SPRTS, includes LEMO connector 
  
  
992Standard Length 10M
  
Additional Lengthper meter 
  
NoteOn ordering an 992 extension lead at the same time as an SPRT the LEMO connector will be fitted to the SPRT.






  


Working SPRT - 909/100Ω 
Includes traceable certificate at Rtpw and Wga and carrying case
  
Quartz 
909Q/100ΩTemperature Range -200°C to 550°C
 Length 480mm
 Length 550mm
 Length 600mm
Metal  
909H/100ΩTemperature Range -80°C to 550°C
 Length 480mm
 Length 550mm
 Length 600mm
Metal  
909L/100ΩTemperature Range -200°C to 165°C
 Length 480mm
 Length 550mm
 Length 600mm
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hand Carry RecommendationWe recommend that these thermometers are hand carried where possible
  
  
Model 992 SPRT Extension Lead 
For Isotech SPRTS, includes LEMO connector 
  
  
992Standard Length 10M
  
Additional Lengthper meter 
  
NoteOn ordering an 992 extension lead at the same time as an SPRT the LEMO connector will be fitted to the SPRT.






  


CUSTOMER:                                           ORDER NO:
  
  
Thermocouple Standards - Platinum/Palladium 
Manufactured by National Physical Laboratory (NPL)
NPL UKAS Calibration included - select from 3 calibration ranges available 
  
  
NPL Pt/Pd T/CTemperature Range 0°C to 1500°C
 7 x 700mm outer ceramic sheath with cold junction
  
Calibration OptionPlease select from 1 of the 3 following calibration ranges available
  
0°C to 1100°CUncertainty of ±0.2°C
Calibrated at Fixed Points Zn, Ag and Cu
  
0°C to 1330°CUncertainty of ±0.2°C from 0°C to 1100°C rising linearly to ±0.55°C at 1330°C
Calibrated at Fixed Points Zn, Ag and Co-C
  
0°C to 1500°CUncertainty of ±0.2°C from 0°C to 1100°C rising linearly to ±0.7°C at 1500°C
Calibrated at Fixed Points Zn, Ag and Pd-C






  


Thermocouple Homogeneity Scanner 881
Dual Heat Pipe Thermocouple Homogeneity Scanner
  
  
Model 881Thermocouple Homogeneity Scanner
  
  
Voltage Supply 100/130V – 50/60Hz
 208/240V – 50/60Hz






  


Thermocouple Standards - Platinum/Platinum Rhodium
Includes 4 point UKAS Calibration up to 1100°C
  
With Cold Junction 
1600 Type RTemperature Range 0°C to 1600°C
 Length 300mm
 Length 600mm
  
1600 Type STemperature Range 0°C to 1600°C
 Length 300mm
 Length 600mm
  
Without Cold Junction 
1600 Type RTemperature Range 0°C to 1600°C
 Length 300mm
 Length 600mm
  
1600 Type STemperature Range 0°C to 1600°C
 Length 300mm
 Length 600mm
  
Calibration Option 
UKASCalibration available up to 1300°C (additional nett)
NPL - 0°C to 1330°CUncertainty of ±0.3°C from 0°C to 1100°C rising linearly to ±0.55°C at 1330°C (additional nett)
Calibrated at Fixed Points Zn, Ag and Co-C (additional nett)
NPL - 0°C to 1500°CUncertainty of ±0.3°C from 0°C to 1100°C rising linearly to ±0.7°C at 1500°C (additional nett)
Calibrated at Fixed Points Zn, Ag and Pd-C (additional nett)
  
  
  
  


Thermocouple Standards - Gold/Platinum
Includes Carrying Case 
  
  
1000Temperature Range 0°C to 1000°C
 With Traceable Calibration at Rtpw and FP Zinc, Aluminium and Silver 
  
1000Temperature Range 0°C to 1000°C
 With NPL UKAS Calibration at FP Zinc, Aluminium and Silver, uncertainty: 0°C-400°C ±0.07°C, 400°C-1000°C ±0.05°C
  
  
  
  
  
Precision Thermometer - microK 
For use with SPRTs, Thermistors and Thermocouples
Includes UKAS Calibration 
  
  
864amicroK GOLD
  
864amicroK 70
  
864amicroK 125
  
910amicroK 250
  
910amicroK 500
  
  
Channel Expander - microsKanner
10 Channel Scanner, expandable up to 90 channels
  
  
913microsKanner
  
  
Voltage Supply Universal power supply allows operation from 90 to 240V 50/60Hz
  
  
  
  
  
Resistance Bridge Calibrator RBC 100 & RBC 400
Includes software for analysis and certificate printing
  
RBC Manual Version 
924-01-01RBC 100 (M)
 Optimised for 25.5Ω Thermometry
  
924-01-02RBC 400 (M)
 Optimised for 100Ω Thermometry
  
RBC Automatic Version 
920-01-01RBC 100 (A) includes carrying case
 Optimised for 25.5Ω Thermometry
  
920-01-02RBC 400 (A) includes carrying case
 Optimised for 100Ω Thermometry
  
  
  
  
  
True Temperature Indicator - TTI 22
Includes Cal Notepad Software for monitoring and logging, RS232 Cable and 2 Lemo Connectors to suit
  
  
926True Temperature Indicator TTI 22
 Temperature Range -250°C to 962°C
  
Selector Switch 
9548 Way Selector Switch for PRT's
  
Semi Standard Pt100'sInclude Carrying Case and Lemo Connector suitable for use with  TTI 22
935-14-13/TTIbTemperature Range -196°C to 250°C
935-14-16/TTIbTemperature Range -100°C to 450°C
935-14-61/TTIbTemperature Range -50°C to 250°C
935-14-72/TTIbTemperature Range -50°C to 670°C
935-14-95H/TTIbTemperature Range -80°C to 670°C
935-14-95L/TTIbTemperature Range -200°C to 165°C
  
Working SPRT'sInclude Carrying Case and Lemo Connector suitable for use with  TTI 22
Metal Clad 909L/100Ω/TTIbTemperature Range -200°C to 165°C
 Length 480mm
Quartz Clad 909Q/100Ω/TTIb Temperature Range -200°C to 550°C
 Length 480mm
  
Accessories 
956/TTI 22Terminal Adaptor
931-22-106Carrying Case (nett)
  
Voltage Supply Universal power supply allows operation from 90 to 240V 50/60Hz
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties






  


milliK Precision Thermometer
Includes Cal Notepad Software for monitoring and logging, RS232 Cable, 2 Lemo Connectors to suit and traceable certificate
  
  
923milliK Precision Thermometer
 Temperature Range -270°C to 1820°C
Semi Standard Pt100'sInclude Carrying Case and fitted Lemo Connector 
935-14-13/TTITemperature Range -196°C to 250°C
935-14-16/TTITemperature Range -100°C to 450°C
935-14-116/TTITemperature Range -100°C to 450°C
935-14-61/TTITemperature Range -50°C to 250°C
935-14-72/TTITemperature Range -50°C to 670°C
935-14-95H/TTITemperature Range -80°C to 670°C
935-14-95L/TTITemperature Range -200°C to 165°C
Working SPRT'sIncludes Carrying Case and fitted Lemo Connector 
Metal Clad 909L/100Ω/TTITemperature Range -200°C to 165°C - Length 480mm 
Quartz Clad 909Q/100Ω/TTITemperature Range -200°C to 550°C - Length 480mm 
Accessories 
956Terminal Adaptor
931-22-102Carrying Case (nett)
Voltage Supply Universal power supply allows operation from 90 to 240V 50/60Hz


SYSTEM CALIBRATION 
Only applicable when millik and semi-standard probe purchased at same time
Temperature RangeCalibration Points/Typical Uncertainty
-196°C to 232°C-196°C (±0.030°C), -38.8°C (±0.015°C), 0.01°C  (±0.015°C), 156°C (±0.025°C),232°C (±0.025°C)
-196°C to 29.76°C-196°C (±0.030°C), -38.8°C (±0.015°C), 0.01°C (±0.015°C), 29.76°C (±0.015°C)
-50°C to 250°C-50°C (±0.025°C), 0.01°C (±0.015°C), 29.76°C (±0.015°C), 156°C (±0.025°C), 250°C (±0.030°C)
-80°C to 419°C-80°C (±0.030°C), -38.8°C  (±0.015°C), 0.01°C  (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C)
0.01°C to 419°C0.01°C (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C)
-80°C to 660°C-80°C (±0.030°C), -38.8°C (±0.015°C), 0.01°C  (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C), 660°C (±0.050°C)
0.01°C to 660°C0.01°C  (±0.015°C), 232°C (±0.025°C), 419°C (±0.040°C), 660°C (±0.050°C)
350°C to 1100°C350°C (±0.8°C), 600°C (±0.8°C), 850°C (±0.8°C), 1100°C (±0.8°C)
350°C to 1300°C350°C (±0.8°C), 700°C (±0.8°C), 1000°C (±0.8°C), 1300°C (±1.8°C)
ADDITIONAL SYSTEM CALIBRATION OPTIONS - Applicable when millik and semi-standard probe purchased at same time
Temperature RangeCalibration Points/Typical Uncertainty
0.01°C to 156°C0.01°C (0.01°C), 156°C (0.015°C)
-38°C to 29.7646°C-38°C (0.015°C), 0.01°C (0.01°C), 29.76°C (0.01°C)
*See Brochure - MILLIK HIGH ACCURACY TEMPERATURE MEASUREMENT 
  






  


millisKanner Channel Expander
Eight Channel Expansion Unit for milliK, maximum of four units per milliK
  
  
914amillisKanner Channel Expander (first unit)
 Includes following cables suitable for connecting milliK to millisKanner
932-42-33Universal Power Suply allows operation from 90 to 240V 50/60Hz (suitable to power up to 4 millisKanners)
914-03-02Digital Connecting Cable
914-02-02milliK to millisKanner linking cable
  
  
914bmillisKanner Channel Expander (subsequent)
 Includes following cables suitable for connecting millisKanner  to milliskanner
914-02-03DC Link Cable (Univeral PSU not required)
914-03-02Digital Connecting Cable
914-02-04millisKanner to millisKanner linking cable






  


AC/DC Standard Resistors - SRA & SRB
Includes Calibration Certificate (3ppm) 
On ordering advise temperature Resistor is to be set at 
  
  
SRA
SRA10Ω
SRA25Ω
SRA100Ω
SRA400Ω
  
SRB1,000Ω
SRB10,000Ω
  
  
Calibration Option 
UKASFrom ±0.3ppm (nett)
UKASSRA 1Ω/5Ω  <±0.09ppm (nett)
UKASSRA 10Ω/25Ω/100Ω  <±0.08ppm (nett)
UKASSRA 400Ω  <±0.1ppm (nett)






  


Resistor Maintenance Bath  
Will house several resistors, please specify number and type
  
  
455Resistor Maintenance Bath
 Temperature Range Dew Point to above 40°C
  
Accessories 
932-19-72SR Oil - 35 Litres required (per Litre)
  
  
Voltage Supply 100/130V – 50/60Hz
 208/240V – 50/60Hz
  
  
  
  


Temperature Controlled AC/DC Resistors - Model 456
  
  
  
456TCFR 10Ω
456TCFR 25Ω
456 TCFR 100Ω
456TCFR 1,000Ω
456TCFR 10,000Ω
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  


Boiling Point Apparatus - Nitrogen
May be adapted for use with liquid argon 
  
  
18205Boiling Point Apparatus Nitrogen
 Temperature Range -185°C to -196°C nominal
  
  
  
  


CUSTOMER:                                           ORDER NO:
  
  
Simple Liquid Nitrogen Apparatus
Liquid Nitrogen not included and must be sourced locally
  
  
461Simple Liquid Nitrogen Apparatus
 Nominal Temperature Range -196°C
  
  
  
  


CUSTOMER:                                           ORDER NO:
  
  
Cryostat Model 459 
Liquid Nitrogen not included and must be sourced locally
  
  
459Cryostat 
 Temperature Range -80°C to -180°C
  
Accessories 
459-01-01Hand Vacuum Pump (nett)
459-01-02Electric Vacuum Pump (nett)
459-01-0335 Litre Cryostat Container (nett)
459-01-0425 Litre Container for topping up (nett)
459-02-13Fill Tube Assembly
  
  
  
  


Stirred Liquid Baths - 915 Parallel Tube
With Eurotherm Controller 0.01°C to 0.1°C resolution, Serial Communications and Cal Note Pad Software.
  
  
915HNo Chiller Supplied
 Temperature Range 30°C to 300°C
Voltage Supply110V – 50/60Hz
 240V – 50/60Hz
  
915MWESupplied with 1 stage wide range chiller
 Temperature Range -30°C to 40°C
Voltage Supply110V – 50Hz
 110V – 60Hz
 240V – 50Hz
 240V – 60Hz
  
915LWSupplied with 2 stage wide range chiller
 Temperature Range -65°C to 40°C
Voltage Supply110V – 50Hz
 110V – 60Hz
 240V – 50Hz
 240V – 60Hz
  
Accessories 
915/01aAluminium Equalising Block 
915/01bCopper Equalising Block
915/02Liquid in Glass Thermometer Support Kit
915/03Monocular and Support 
915/05Calibration Tube Cover and Equalising Block Support
796-05-03Thermometer Stand Kit
  
915/07Medium Silicon Oil  40°C to 180°C (per Litre)
915/08High Silicon Oil 150°C to 250°C (per Litre)
915/09Very High Silicon Oil 40°C to 288°C (per Litre)
  
915/DIncreased Depth Calibration Tube Assembly
915/EHigh Stability Controller (nett)
  
 7 Litres Oil Required per Liquid Bath






  


Stirred Liquid Baths - 785 Parallel Tube
With Eurotherm Controller 0.01°C resolution over full range, Serial Communications and Cal Note Pad Software.
  
  
785HTemperature Range 30°C to 300°C
  
785MTemperature Range -40°C to 125°C
  
785LTemperature Range -80°C to 125°C
  
Voltage Supply110V – 50/60Hz
 240V – 50/60Hz
  
Accessories 
915/01aAluminium Equalising Block 
915/01bCopper Equalising Block
785-02Liquid in Glass Thermometer Support Kit
796-03Monocular and Support 
796-05-03Thermometer Stand Kit
785-02-20Blackbody Assembly
785-05-01A11-50 Water Triple Point Cell Kit
  
915/07Medium Silicon Oil  40°C to 180°C (per Litre)
915/08High Silicon Oil 150°C to 250°C (per Litre)
915/09Very High Silicon Oil 40°C to 288°C (per Litre)
  
  
  
 8½ Litres Oil Required per Liquid Bath
  
  
  
  
  
Stirred Liquid Baths - Accessories for 785 and 915 
  
  
  
Fixed Point Calibration ITS-90 Cell Basket Assemblies
  
915-05-43Small Mercury Cell Kit (nett)
915-05-44Large Mercury Cell Kit (nett)
915-05-41Small Water Triple Point Cell Kit (nett)
915-05-40Large Water Triple Point Cell Kit (nett
915-05-38Large Gallium Cell Kit (nett
915-05-39Small Gallium Cell Kit (nett)
915-05-42Slim Cell Kit (nett)
  
Chiller Options 
  
915/10Single Stage Wide Range Chiller
 Temperature Range  -30°C to 40°C
  
Voltage Supply110V – 50Hz (nett)
 110V – 60Hz (nett)
 240V – 50Hz (nett)
 240V – 60Hz (nett)
  
915/11Dual Stage Wide Range Chiller
 Temperature Range -65°C to 40°C
  
Voltage Supply110V – 50Hz (nett)
 110V – 60Hz (nett)
 240V – 50Hz (nett)
 240V – 60Hz (nett)
  
  
  
  
  
Stirred Liquid Baths - Orion 
With Eurotherm Controller 0.01°C to 0.1°C resolution, Lid Accessory, Serial Communications and Cal Note Pad Software.
  
  
796HTemperature Range 30°C to 300°C
  
796MTemperature Range -40°C to 125°C 
  
796LTemperature Range -80°C to 125°C 
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
Accessories 
796-05-02Spare Liquid Volume Lid
798-05-02AAluminum Equalising Block
798-05-02BCopper Equalising Block
798-05-03Twin Cell Holder for B12/40/210 Water Triple Point Cell
798-05-04Thermometer Support Kit
796-05-01Dual Large Water Triple Point Cell Holder
796-03Monocular and Support
796-02-10Overflow Adaptor 
796-05-03Thermometer Stand Kit
796-05-04Large Gallium Cell Holder
796-05-05Slim Gallium Cell Holder
798-02-58Blackbody Assembly
  
915/07Medium Silicon Oil  40°C to 180°C (per Litre)
915/08High Silicon Oil 150°C to 250°C (per Litre)
915/09Very High Silicon Oil 40°C to 288°C (per Litre)
936-06-07C10 Silicon Oil -35°C to 140°C (per Litre)
580-06-09C20 Silicon Oil Ambient to 200°C (per Litre)
  
 8.5 Litres Oil Required per Liquid Bath
  
  
  
  
  
Stirred Liquid Baths - Hydra 
With Eurotherm Controller 0.01°C to 0.1°C resolution, Lid Assembly, Serial Communications and Cal Note Pad Software.
  
  
798HTemperature Range 30°C to 300°C
  
798MTemperature Range -40°C to 125°C 
  
798LTemperature Range -80°C to 125°C 
  
Voltage Supply110V – 50/60Hz
 230V – 50/60Hz
  
Accessories 
796-05-02Spare Liquid Volume Lid
798-05-02AAluminum Equalising Block
798-05-02BCopper Equalising Block
798-05-02CSpecial Aluminium Equalising Block  (consult Isotech)
798-05-02DSpecial Copper Equalising Block (consult Isotech)
798-05-03Twin Cell Holder for B12/40/210 Water Triple Point Cell
798-05-04Thermometer Support Kit
796-05-01Dual Large Water Triple Point Cell Holder
796-05-03Thermometer Stand Kit
798-02-58Blackbody Assembly
  
915/07Medium Silicon Oil  40°C to 180°C (per Litre)
915/08High Silicon Oil 150°C to 250°C (per Litre)
915/09Very High Silicon Oil 40°C to 288°C (per Litre)
936-06-07C10 Silicon Oil -35°C to 140°C (per Litre)
580-06-09C20 Silicon Oil Ambient to 200°C (per Litre)
  
 5 Litres Oil Required per Liquid Bath
  
  
  
  
  
Stirred Ice/Water Bath 813 
350mm Immersion Depth, 8 Litre Capacity
  
  
813Stirred Ice/Water Bath
 Temperature Range 0°C
  
Accessories 
814/01bCopper Equalising Block
814/02Mercury Thermometer Support Kit
814-06-02Small Water Triple Point Cell Kit (nett)
814-06-04Large Water Triple Point Cell Kit (nett)
  
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz






  


Large Volume Calibration Bath
Includes Serial Communications and Cal Notepad
  
  
820Large Volume Calibration Bath
 Temperature Range 30°C to 200°C
  
Accessories 
820/01Standard Resistor Holder
820/02Aluminium Equalising Block
820/02 SSpecially Drilled Equalising Block
820/03Liquid in Glass Support Kit 
  
915/07Medium Silicon Oil  40°C to 180°C (per Litre)
915/08High Silicon Oil 150°C to 250°C (per Litre)
915/09Very High Silicon Oil 40°C to 288°C (per Litre)
932-19-72SR for Standard Resistors (per Litre)
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
  
  
  
  
Liquid Selection Guide 
For Hydra, Orion, 785 and 915 
  
  
915/07Medium Silicon Oil  40°C to 180°C (per Litre)
915/08High Silicon Oil 150°C to 250°C (per Litre)
915/09Very High Silicon Oil 40°C to 288°C (per Litre)
936-06-07C10 Silicon Oil -35°C to 140°C (per Litre)
580-06-09C20 Silicon Oil 20°C to 200°C (per Litre)
  
  
  
Fume Extraction Provision for adequate fume extraction needs to be made when using any open liquid bath
  
 Requirement varies depending on the liquid used and the temperature range
  
  
  
  
  
Fluidized Calibration Bath 
Supplied with 25kgs Alumina Powder, Calibration Tube 875/02, 875/15 Equalising Block, Serial Communications and Cal Notepad Software
  
  
875Fluidized Calibration Bath
 Temperature Range 50°C to 700°C
  
Voltage Supply208/240V – 50/60Hz
  
Accessories 
875/03Compressor and Connecting Tube (nett)
875/0425kg Container Alumina Powder
875/06Liquid in Glass Thermometer Support Gantry includes 875/07
875/07Additional Multi-Tube Probe Holder
875/08Monocular and Support
875/15Additional Equalising Block (8x8mm pockets x 240mm deep)
  
  
 
  
  
Thermocouple Calibration Furnace - Saturn
With Standard Equalising Block, Spare Set Windings, Serial Communications and Cal Notepad Software
  
  
877Thermocouple Calibration Furnace - Saturn
 Temperature Range 100°C to 1300°C
  
Voltage Supply208/240V – 50/60Hz
 115V – 50/60Hz 
  
Accessories 
877/01Replacement Standard Equalising Block - 4 x 8mm x 4 x 6mm i.d. - 180mm leg length
877/01SSpecial Equalising Block - 16 x 6mm i.d. - 180mm leg length
877/01ESpecial Equalising Block - other configurations - (consult Isotech)
877/02Platinum Foil Temperature Barrier (nett)
935-14-130Replacement Control Thermocouple Type R
  
  
  
  
  
ITS-90 Isothermal Towers 
Integrated ITS-90 Fixed Point Calibration System with Certificate of Purity and a Melt and Freeze Curve.  Serial Communications and Cal Notepad Software included
  
  
490Indium 156.5985°C
491Tin 231.928°C
492Zinc 419.527°C
493Aluminium 660.323°C
  
  
Special Package Price 
Tin, Zinc and Aluminium systems when ordered together
  
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
  
Calibration OptionUKAS Fixed Point Cell Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  
  
Slim Fixed Point Cells Sealed 
99.9999% Pure.  With Certificate of Conformity
  
Quartz Clad Slim Fixed Point Cells 
Require to be hand carried 
17668 QSIndium 156.5985°C
17669 QSTin 231.928°C
17671 QSZinc 419.527°C
17672 QSAluminum 660.323°C
17673 QSSilver 961.78°C
17674 QSCopper 1084.62°C
  
Metal Clad Slim Fixed Point Cells 
Transportable 
17401 MGallium 29.7646°C
17724 MMercury -38.8344°C
17668 MLIndium 156.5985°C
17669 MLTin 231.928°C
17671 MLZinc 419.527°C
17672 MLAluminum 660.323°C
  
Accessories 
510-05-00Inconel basket including insulators for use with Medusa - Indium to Zinc (nett)
511-05-01Inconel basket including insulators for use with Medusa 511 - Aluminium (nett)
426-04-00Inconel basket including insulators for use with Oberon - Aluminium to Copper (nett)
  
Calibration OptionTraceable and UKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
Hazardous               (consult Isotech)Due to the hazardous nature of Gallium and Mercury these cells are packed and shipped in accordance to IATA specification
  
  
  
  
  
Water Triple Point Cells 
With Certificate of Conformity  
  
  
B8/30/130Temperature, 0.01°C
B12/40/210Temperature, 0.01°C
B12/46/210Temperature, 0.01°C
  
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  
  
POTTS - Europa-6 
Includes Site Indicator, Semi-Standard 935-14-82/DB, Serial Communications, Cal Note Pad Software and Traceable Certificate.
  
  
520Europa-6 POTTS
 Temperature Range 65°C below ambient to 140°C
  
Metal Block Bath 
951-02-15Standard Insert - 2x4.5mm, 2x6.4mm, 1x8mm, 1x9.5mm x 157mm deep
951-02-15aBlank Insert
951-02-15cNon Standard Insert (consult Isotech)
951-06-07Insert Type B - 1x13mm, 1x10mm, 1x8mm, 1x5mm and 1.3.5mm x 157mm deep
951-06-08Insert Type C - 1x8mm, 6x6.5mm x 157mm deep
935-14-82/DBAdditional Semi Standard PRT
UKAS5 Point Comparison Calibration  (nett)
Stirred Liquid Bath/Stirred Ice/Water Bath
951-06-01Stirred Liquid Container for alcohol’s, water and oils
951-06-03Liquid in Glass Thermometer Support Kit
Blackbody Source 
951-06-04Blackbody Target
Surface Sensor Calibrator 
951-06-02Surface Sensor Calibrator Kit
ITS-90 Fixed Point Apparatus 
17724 MSlim Mercury Triple Point Cell and Insulation Assembly 
17401 MSlim Gallium Melt Point Cell 
B8/30/130Water Triple Point Cell, Container and 3 caps
Accessories 
520-05-01C10 Oil (-35°C to 140°C) 0.1 Litre required
932-12-55Replacement Liquid Container Magnetic Follower (Qty 5)
935-14-83Replacement Surface Sensor Probe
951-02-19Replacement Surface Sensor Insert
951-02-29Slim WTP Cell Container (nett)
951-02-30Slim WTP Cell Container Caps (Qty 3) (nett)
520-03-00Slim Mercury Cell Insulation Assembly  (nett)
931-22-111Carrying Case with wheels and pull out handle (nett)
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  
  
POTTS - Oceanus-6 
Includes Site Indicator, Semi-Standard 935-14-85/DB, Serial Communications, Cal Note Pad Software, Timer and Traceable Certificate.
  
  
580Oceanus-6 POTTS
 Temperature Range 45°C below ambient to 140°C
  
Metal Block Bath 
580-06-03Standard Insert - 6x8mm x 250mm deep
580-06-04Blank Insert
580-06-05Non Standard Insert (consult Isotech)
580-06-06Adjustable Equalising Block - 6x8mm x 157mm deep
935-14-85/DBAdditional Semi Standard PRT
UKAS5 Point Comparison Calibration  (nett)
Stirred Liquid Bath/Stirred Ice/Water Bath 
580-06-07Stirred Liquid Container for alcohol’s, water and oils
580-06-00Liquid in Glass Thermometer Support Kit
Blackbody Source 
580-02-12Blackbody Target
Surface Sensor Calibrator 
580-06-08Surface Sensor Calibrator Kit (consists of probe and insert)
ITS-90 Fixed Point Apparatus 
17401Gallium Melt Point Cell & Support
B12/46/210Water Triple Point Cell & Supports
Accessories 
936-06-07C10 Oil (-35°C to 150°C) 1 Litre required
932-12-74Replacement Liquid Container Magnetic Follower (Qty 5)
935-14-114Replacement Surface Sensor Probe
580-02-11Replacement Surface Sensor Insert
580-06-01WTP Cell Support (nett)
580-06-02Gallium Cell Support (nett)
931-22-58Storage Case (nett)
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  
  
POTTS - Medusa 510  
Includes Site Indicator, Semi-Standard 935-14-95H/DB, Serial Communications, Cal Note Pad Software, Timer and Traceable Certificate.
  
  
510Medusa 510 POTTS
 Temperature Range 30°C to 550°C
  
Metal Block Bath 
510-06-01Standard Insert - 6x8mm x 250mm deep
510-06-02Blank Insert
510-06-03Non Standard Insert (consult Isotech)
510-06-04Adjustable Equalising Block - 6x8mm x 157mm deep
935-14-95H/DBAdditional Semi Standard PRT
UKAS5 Point Comparison Calibration  (nett)
Blackbody Source 
510-06-05Blackbody Target
Surface Sensor Calibrator 
510-06-06Surface Sensor Calibrator Kit (consists of probe and insert)
ITS-90 Fixed Point Apparatus - Metal Clad Slim Fixed Point Cells
Transportable 
17668 MLSlim Metal Clad Indium Fixed Point Cell
17669 MLSlim Metal Clad Tin Fixed Point Cell
17671 MLSlim Metal Clad Zinc Fixed Point Cell
ITS-90 Fixed Point Apparatus - Quartz Clad Slim Fixed Point Cells
Require to be hand carried 
17668 QSSlim Quartz Clad Indium Fixed Point Cell
17669 QSSlim Quartz Clad Tin Fixed Point Cell
17671 QSSlim Quartz Clad Zinc Fixed Point Cell
Accessories 
935-14-66Replacement Standard Thermocouple for BB Target
935-14-118Replacement Surface Sensor Probe
510-02-02Replacement Surface Sensor Calibrator Insert
510-05-00Slim Cell Holder including Insulators - Indium to Zinc (nett)
931-22-58Storage Case (nett)
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  
  
POTTS - Medusa 511  
Includes Site Indicator, Semi-Standard 935-14-95H/DB, Serial Communications, Cal Note Pad Software, Timer and Traceable Certificate.
  
511Medusa 511 POTTS
 Temperature Range 50°C to 700°C
  
Metal Block Bath 
511-06-01Standard Insert - 6x8mm x 250mm deep
511-06-02Blank Insert
511-06-03Non Standard Insert (consult Isotech)
511-06-04Adjustable Equalising Block - 6x8mm x 157mm deep
935-14-95H/DBAdditional Semi Standard PRT
UKAS5 Point Comparison Calibration  (nett)
Blackbody Source 
511-06-05Blackbody Target
Surface Sensor Calibrator 
511-06-06Surface Sensor Calibrator Kit (consists of probe and insert)
ITS-90 Fixed Point Apparatus - Metal Clad Slim Fixed Point Cells
Transportable 
17668 MLSlim Metal Clad Indium Fixed Point Cell
17669 MLSlim Metal Clad Tin Fixed Point Cell
17671 MLSlim Metal Clad Zinc Fixed Point Cell
17672 MLSlim Metal Clad Aluminium Fixed Point Cell
ITS-90 Fixed Point Apparatus - Quartz Clad Slim Fixed Point Cells
Require to be hand carried 
17668 QSSlim Quartz Clad Indium Fixed Point Cell
17669 QSSlim Quartz Clad Tin Fixed Point Cell
17671 QSSlim Quartz Clad Zinc Fixed Point Cell
17672 QSSlim Quartz Clad Aluminium Fixed Point Cell
Accessories 
935-14-66Replacement Standard Thermocouple for BB Target
935-14-118Replacement Surface Sensor Probe
510-02-02CReplacement Surface Sensor Calibrator Insert
510-05-00Slim Cell Holder including Insulators - Indium to Zinc (nett)
511-05-01Slim Cell Holder including Insulators - Alunimium (nett)
931-22-58Storage Case (nett)
  
Voltage Supply108/130V – 50/60Hz
 208/240V – 50/60Hz
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  
  
POTTS - Oberon 
Includes Serial Communications and Cal NotePad Software
  
  
426Oberon POTTS
 Temperature Range 450°C to 1100°C
  
Voltage Supply110V – 50/60Hz only
  
Metal Block Bath 
426-06-05Adjustable Equalising Block - 6x8mm x 160mm deep
  
ITS-90 Fixed Point Apparatus - Quartz Clad Slim Fixed Point Cells
Require to be hand carried 
17672 QSSlim Quartz Clad Aluminium Fixed Point Cell
17673 QSSlim Quartz Clad Silver Fixed Point Cell
17674 QSSlim Quartz Clad Copper Fixed Point Cell
  
Accessories 
426-04-00Inconel Cell Basket including Insulators - Aluminium to Copper - for use with Oberon (nett)
935-19-63Isolation Transformer to allow operation from 240V supply (nett)
935-19-71Isolation Transformer to allow operation from 220V supply (nett)
  
Calibration OptionUKAS Fixed Point Calibration available refer to Calibration Price List for more information on temperature ranges and uncertainties
  
  
  
  
  
Calibration Software  
  
  
  
Cal NotepadPermits connection of both an indicator and the calibration bath, view data on configurable chart displays, log data to file and control the bath
  
I Cal EasyCan automatically calibrate up to 20 temperature sensors, calculate coefficients and print own design certificates
  
I Cal Easy PlusCan automatically calibrate up to 20 temperature sensors, calculate coefficients and print own design certificates. Includes additional drivers for third party instruments.  Before ordering consult Isotech.
  
Icarus Designed to calculate SPRT coefficients, print and design own certificates


DATASHEET MANUAL PDF DOWNLOAD

제품 상담, 견적, AS 문의는 공식 인증 대리점 GENIUS INDUSTRIES에 문의하세요!

대한민국 No.1 산업장비 공급채널 지니어스인더스트리
070-8888-7179 / jiny@geniuss.kr




제품상담 : 070-8888-7179 (친한친구)
E-mail : info@geniuss.kr
Mon - Fri  09:00 - 18:00
Sat.Sun.Red-Day Off

🌍 지니어스인더스트리

💫 GENIUS INDUSTRIES


📍 서울시 서초구 동산로6길 11, 희빌딩 2층
Tel. 02-572-7179 | Fax. 0303-3444-7179

대표 : 박병진 | 📋 사업자등록증 | 💳 통장사본


(주)지니어스허브

Company No. : 583-86-02680
Network No. : 2024-SeoulSeocho-0030

카카오톡 채널 채팅하기 버튼