RKC SA100 디지털 온도 컨트롤러
RKC SA100 디지털 온도 컨트롤러
RKC SA100 Digital controllers (Temperature controllers)
- Measurement accuracy: ±0.3% of displayed value
- Sampling time: 0.5 sec.
- DIN rail mounting type (Also installable on a panel)
- Plug-in construction
클릭 하시면 이동합니다.
알케이씨 ・ RKC
SA100
디지털 온도 컨트롤러
SA100 Digital controllers (Temperature controllers)
Main features
- DIN rail mounting type temperature controller
![]() | Installable on the DIN rail inside the control cabinet. Removable terminal socket for easy maintenance. |
- Control state discriminating type self-tuning
![]() | PID parameters are automatically tuned when control is determined to be disturbed Autotuning function is also available |
- Two outputs can be assigned to control output, alarm output, or analog retransmission output
![]() | This instrument can be used as a temperature controller, an alarm, or an overtemperature protection device depending on the output assignment. |
Main specification
- Number of Inputs :1 point
- Input type : ※See the Input Range Code for the input range.
1)Thermocouple : K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
2)RTD: Pt100 or JPt100
3)DC voltage: 0 to 5V dc, 1 to 5V dc
4)DC current: 0 to 20mA dc, 4 to 20mA dc ※ A 250Ω external resistor is required.
- Sampling time: 0.5 sec.
- Measurement accuracy:±(0.3% of displayed value+1 digit) ※Depends on the input and the range.
- Output (OUT1) ※To be assigned from a control output, an alarm output, or an analog retransmission output.
1) Relay contact output : 1a contact
2) Voltage pulse output for SSR driving: 0/12V dc
3) DC Current output : 0 to 20mA, 4 to 20mA dc
<Specification for Optional Functions>
- Output2(OUT2)※To be assigned from a control output or an alarm output.
1) Relay contact output : 1a contact
2) Voltage pulse output for SSR driving: 0/12V dc
- Alarm outputs (max.2 points): Temperature alarm or Control loop break alarm
- External contact inputs (max.2 points): RUN/STOP switching or SV1/SV2 switching
- Communication function: Communication method RS-485
<General Specification>
- Power supply voltage (Rating): 100 to 240V ac/24Vac/24Vdc
- Ambient temperature: 0 to 50°C
- weight: Approx.120g (excluding a socket)
- Safety standards: UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE Marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive EN61326-1
RCM EN55011
External dimensions







SA100 RKC SA100 SA100 RKC 알케이씨 SA100 SA100 알케이씨
가격이 궁금하신가요?
더 많은 자료는?


지니어스인더스트리가 취급하는 대부분의 제품은 사업자 간 거래(B2B) 목적의 산업·연구용 전문 계측 장비입니다.
모든 제품은 주문 제작 또는 해외/본사 주문을 통해 공급되고 있으며 실제 현장/시험 환경에서 사용되는 특성상, 장비 개봉, 전원 인가, 설치/시운전, 교정(캘리브레이션) 진행 등으로 제품의 신뢰도와 가치가 달라지기 때문에 일반 소비재와 달리 단순 변심 사유의 반품·환불이 어렵습니다.
다만 초기 제품 하자(동일 모델 대비 명백한 불량, 운송 중 파손, 사양 상이 등)가 확인되는 경우에는 수령 후 [7일 이내] 연락 주시면 점검 후 조치 또는 A/S 절차를 안내해 드리고 있습니다.
단순 변심, 사양 선택 착오, 내부 사정(예: 예산/프로젝트 변경 등)과 같은 구매자 사유로 반품을 요청하시는 경우에는 반품이 제한되며, 예외적으로 협의가 진행될 경우에도 왕복 운송비, 검수 비용, 감가 비용 및 재입고 수수료 등이 청구될 수 있습니다.
구체적인 거래 조건(납기, A/S 범위, 교환 가능 여부 등)은 발행된 견적서, 발주서 확인 메일, 납품서 등에 명시된 내용을 우선합니다.
도움이 필요한 경우 견적서에 명시된 지니어스 영업부 담당자에게 문의해 주시기 바랍니다.
알케이씨 ・ RKC
SA100
디지털 온도 컨트롤러
SA100 Digital controllers (Temperature controllers)
Main features
- DIN rail mounting type temperature controller
![]() | Installable on the DIN rail inside the control cabinet. Removable terminal socket for easy maintenance. |
- Control state discriminating type self-tuning
![]() | PID parameters are automatically tuned when control is determined to be disturbed Autotuning function is also available |
- Two outputs can be assigned to control output, alarm output, or analog retransmission output
![]() | This instrument can be used as a temperature controller, an alarm, or an overtemperature protection device depending on the output assignment. |
Main specification
- Number of Inputs :1 point
- Input type : ※See the Input Range Code for the input range.
1)Thermocouple : K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
2)RTD: Pt100 or JPt100
3)DC voltage: 0 to 5V dc, 1 to 5V dc
4)DC current: 0 to 20mA dc, 4 to 20mA dc ※ A 250Ω external resistor is required.
- Sampling time: 0.5 sec.
- Measurement accuracy:±(0.3% of displayed value+1 digit) ※Depends on the input and the range.
- Output (OUT1) ※To be assigned from a control output, an alarm output, or an analog retransmission output.
1) Relay contact output : 1a contact
2) Voltage pulse output for SSR driving: 0/12V dc
3) DC Current output : 0 to 20mA, 4 to 20mA dc
<Specification for Optional Functions>
- Output2(OUT2)※To be assigned from a control output or an alarm output.
1) Relay contact output : 1a contact
2) Voltage pulse output for SSR driving: 0/12V dc
- Alarm outputs (max.2 points): Temperature alarm or Control loop break alarm
- External contact inputs (max.2 points): RUN/STOP switching or SV1/SV2 switching
- Communication function: Communication method RS-485
<General Specification>
- Power supply voltage (Rating): 100 to 240V ac/24Vac/24Vdc
- Ambient temperature: 0 to 50°C
- weight: Approx.120g (excluding a socket)
- Safety standards: UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE Marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive EN61326-1
RCM EN55011
External dimensions







SA100 RKC SA100 SA100 RKC 알케이씨 SA100 SA100 알케이씨
가격이 궁금하신가요?
더 많은 자료는?


지니어스인더스트리가 취급하는 대부분의 제품은 사업자 간 거래(B2B) 목적의 산업·연구용 전문 계측 장비입니다.
모든 제품은 주문 제작 또는 해외/본사 주문을 통해 공급되고 있으며 실제 현장/시험 환경에서 사용되는 특성상, 장비 개봉, 전원 인가, 설치/시운전, 교정(캘리브레이션) 진행 등으로 제품의 신뢰도와 가치가 달라지기 때문에 일반 소비재와 달리 단순 변심 사유의 반품·환불이 어렵습니다.
다만 초기 제품 하자(동일 모델 대비 명백한 불량, 운송 중 파손, 사양 상이 등)가 확인되는 경우에는 수령 후 [7일 이내] 연락 주시면 점검 후 조치 또는 A/S 절차를 안내해 드리고 있습니다.
단순 변심, 사양 선택 착오, 내부 사정(예: 예산/프로젝트 변경 등)과 같은 구매자 사유로 반품을 요청하시는 경우에는 반품이 제한되며, 예외적으로 협의가 진행될 경우에도 왕복 운송비, 검수 비용, 감가 비용 및 재입고 수수료 등이 청구될 수 있습니다.
구체적인 거래 조건(납기, A/S 범위, 교환 가능 여부 등)은 발행된 견적서, 발주서 확인 메일, 납품서 등에 명시된 내용을 우선합니다.
도움이 필요한 경우 견적서에 명시된 지니어스 영업부 담당자에게 문의해 주시기 바랍니다.
연관상품






